8.6  Front Panel Support 
The Intel
®
 Server Board S5500WB supports SSI standard front panel boards. The front panel 
support is provided by a SSI compatible 2x12-pin signal connector. The front panel connector 
supports the following diagnostic LEDs. 
Table 52. Standard Front Panel Functionality 
LED 
Color 
Condition 
What It Means 
Power/Sleep 
Green 
On 
Power on or S0 sleep 
Green 
Blink 
S1 sleep  
 
Off 
Off (also sleep S5 modes) 
Status 
Green 
On 
System ready/No alarm 
Green 
Blink 
System ready, but degraded: redundancy lost such as power 
supply or fan failure; non-critical temp/voltage threshold; battery 
failure; or predictive PS failure.  
Amber 
On 
Critical alarm: Voltage, thermal, or power fault; CPU1 missing; 
insufficient power unit redundancy resource offset asserted 
Amber 
Blink 
Non-Critical failure: Critical temp/voltage threshold; VDR hot 
asserted; min number fans not present or failed 
 
Off 
AC power off: System unplugged 
AC power on: System powered off and in standby, no prior 
degraded\non-critical\critical state 
HDD 
Green 
Blink 
HDD access 
Amber 
Not Supported 
HDD fault 
Amber 
Not Supported 
Predictive failure, rebuild, identify 
 
Off 
No access  
LAN #1 - Activity 
Green 
On 
LAN link/ no access 
Green 
Blink 
LAN access 
 
Off 
Idle 
LAN #2 - Activity 
Green 
On 
LAN link/ no access 
Green 
Blink 
LAN access 
 
Off 
Idle 
Identification 
Blue 
On 
Front panel chassis ID button pressed 
Blue 
Blink 
Unit selected for identification via software 
 
Off 
No identification