8.6 Front Panel Support
The Intel
®
Server Board S5500WB supports SSI standard front panel boards. The front panel
support is provided by a SSI compatible 2x12-pin signal connector. The front panel connector
supports the following diagnostic LEDs.
supports the following diagnostic LEDs.
Table 52. Standard Front Panel Functionality
LED
Color
Condition
What It Means
Power/Sleep
Green
On
Power on or S0 sleep
Green
Blink
S1 sleep
Off
Off (also sleep S5 modes)
Status
Green
On
System ready/No alarm
Green
Blink
System ready, but degraded: redundancy lost such as power
supply or fan failure; non-critical temp/voltage threshold; battery
failure; or predictive PS failure.
supply or fan failure; non-critical temp/voltage threshold; battery
failure; or predictive PS failure.
Amber
On
Critical alarm: Voltage, thermal, or power fault; CPU1 missing;
insufficient power unit redundancy resource offset asserted
insufficient power unit redundancy resource offset asserted
Amber
Blink
Non-Critical failure: Critical temp/voltage threshold; VDR hot
asserted; min number fans not present or failed
asserted; min number fans not present or failed
Off
AC power off: System unplugged
AC power on: System powered off and in standby, no prior
degraded\non-critical\critical state
AC power on: System powered off and in standby, no prior
degraded\non-critical\critical state
HDD
Green
Blink
HDD access
Amber
Not Supported
HDD fault
Amber
Not Supported
Predictive failure, rebuild, identify
Off
No access
LAN #1 - Activity
Green
On
LAN link/ no access
Green
Blink
LAN access
Off
Idle
LAN #2 - Activity
Green
On
LAN link/ no access
Green
Blink
LAN access
Off
Idle
Identification
Blue
On
Front panel chassis ID button pressed
Blue
Blink
Unit selected for identification via software
Off
No identification