Intel S1400SP4 BBS1400SP4 Manual De Usuario

Los códigos de productos
BBS1400SP4
Descargar
Página de 159
Appendix C: POST Code Diagnostic LED Decoder 
Intel® Server Board S1400SP TPS 
 
 
Revision 1.0 
Intel order number G64248-001 
136 
POST Memory Initialization MRC Diagnostic Codes 
There are two types of POST Diagnostic Codes displayed by the MRC during memory 
initialization; Progress Codes and Fatal Error Codes.  
 
The MRC Progress Codes are displayed to the Diagnostic LEDs that show the execution point 
in the MRC operational path at each step. 
Table 64. MRC Progress Codes 
Checkpoint 
Diagnostic LED Decoder 
Description 
1 = LED On, 0 = LED Off 
Upper Nibble 
Lower Nibble 
MSB   
 
 
 
 
  LSB 
8h  4h  2h  1h  8h  4h  2h  1h 
LED 
#7  #6  #5  #4  #3  #2  #1  #0 
MRC Progress Codes 
B0h 
Detect DIMM population 
B1h 
Set DDR3 frequency 
B2h 
Gather remaining SPD data 
B3h 
Program registers on the memory controller level 
B4h 
Evaluate RAS modes and save rank information 
B5h 
Program registers on the channel level 
B6h 
Perform the JEDEC defined initialization sequence 
B7h 
Train DDR3 ranks 
B8h 
Initialize CLTT/OLTT 
B9h 
Hardware memory test and init 
BAh 
Execute software memory init 
BBh 
Program memory map and interleaving 
BCh 
Program RAS configuration 
BFh 
MRC is done 
 
Memory Initialization at the beginning of POST includes multiple functions, including: discovery, 
channel training, validation that the DIMM population is acceptable and functional, initialization 
of the IMC and other hardware settings, and initialization of applicable RAS configurations. 
 
When a major memory initialization error occurs and prevents the system from booting with data 
integrity, a beep code is generated, the MRC will display a fatal error code on the diagnostic 
LEDs, and a system halt command is executed. Fatal MRC error halts do NOT change the state 
of the System Status LED, and they do NOT get logged as SEL events. The following table lists 
all MRC fatal errors that are displayed to the Diagnostic LEDs: