Platform Management Functional Overview 
Intel® Server Board S1400SP TPS 
 
 
Revision 1.0 
Intel order number G64248-001 
 
54 
The BMC provides FRU device command access to its own FRU device and to the FRU 
devices throughout the server. The FRU device ID mapping is defined in the Platform Specific 
Information
. The BMC controls the mapping of the FRU device ID to the physical device 
  
6.10  System Event Log (SEL) 
The BMC implements the system event log as specified in the Intelligent Platform Management 
Interface Specification, 
Version 2.0. The SEL is accessible regardless of the system power state 
through the BMC's in-band and out-of-band interfaces. 
The BMC allocates 65,502 bytes (approximately 64 KB) of non-volatile storage space to store 
system events. The SEL timestamps may not be in order. Up to 3,639 SEL records can be 
stored at a time. Any command that results in an overflow of the SEL beyond the allocated 
space is rejected with an “Out of Space” IPMI completion code (C4h). 
 
Events logged to the SEL can be viewed using Intel
®
’s SELVIEW utility, Embedded Web Server, 
and Active System Console. 
6.11  System Fan Management 
The BMC controls and monitors the system fans. Each fan is associated with a fan speed 
sensor that detects fan failure and may also be associated with a fan presence sensor for hot-
swap support. For redundant fan configurations, the fan failure and presence status determines 
the fan redundancy sensor state. 
 
The system fans are divided into fan domains, each of which has a separate fan speed control 
signal and a separate configurable fan control policy. A fan domain can have a set of 
temperature and fan sensors associated with it. These are used to determine the current fan 
domain state.  
 
A fan domain has three states: sleep, nominal, and boost. The sleep and boost states have 
fixed (but configurable through OEM SDRs) fan speeds associated with them. The nominal 
state has a variable speed determined by the fan domain policy. An OEM SDR record is used to 
configure the fan domain policy. 
 
System fan speeds are controlled through pulse width modulation (PWM) signals, which are 
driven separately for each domain by integrated PWM hardware. Fan speed is changed by 
adjusting the duty cycle, which is the percentage of time the signal is driven high in each pulse 
 
6.11.1 
Thermal and Acoustic Management 
The S1400SP offers multiple thermal and acoustic management features to maintain 
comprehensive thermal protection as well as intelligent fan speed control. The features can be 
adjusted in BIOS interface with path BIOS Advanced System Acoustic and Performance 
Configuration
This feature refers to enhanced fan management to keep the system optimally cooled while 
reducing the amount of noise generated by the system fans. Aggressive acoustics standards 
might require a trade-off between fan speed and system performance parameters that