Intel® Server Board S1400SP TPS 
Platform Management Functional Overview 
Revision 1.0 
 
 
Intel order number G64248-001 
61 
setup option to allow one of these baseboard ports to be dedicated to the BMC for 
manageability purposes. When this is enabled, that port is hidden from the OS. 
6.12.3.2.3  Concurrent Server Management Use of Multiple Ethernet Controllers  
The BMC FW supports concurrent OOB LAN management sessions for the following 
combination: 
  2 on-board NIC ports  
  1 on-board NIC and the optional dedicated RMM4 add-in management NIC. 
  2 on-board NICs and optional dedicated RMM4 add-in management NIC. 
 
All NIC ports must be on different subnets for the above concurrent usage models. MAC 
addresses are assigned for management NICs from a pool of up to 3 MAC addresses allocated 
specifically for manageability.  
 
The Intel
®
 Server Board S1400SP4 has seven MAC addresses programmed at the factory. 
MAC addresses are assigned as follows:  
•  NIC 1 MAC address (for OS usage) 
•  NIC 2 MAC address = NIC 1 MAC address + 1 (for OS usage) 
•  NIC 3 MAC address = NIC 1 MAC address + 2 (for OS usage) 
•  NIC 4 MAC address = NIC 1 MAC address + 3 (for OS usage) 
•  BMC LAN channel 1 MAC address = NIC1 MAC address + 4 
•  BMC LAN channel 2 MAC address = NIC1 MAC address + 5 
•  BMC LAN channel 3 (RMM) MAC address = NIC1 MAC address + 6 
 
The Intel
®
 Server Board S1400SP2 has five MAC addresses programmed at the factory. MAC 
addresses are assigned as follows: 
  NIC 1 MAC address (for OS usage) 
  NIC 2 MAC address = NIC 1 MAC address + 1 (for OS usage) 
  BMC LAN channel 1 MAC address = NIC1 MAC address + 2 
  BMC LAN channel 2 MAC address = NIC1 MAC address + 3 
  BMC LAN channel 3 (RMM) MAC address = NIC1 MAC address + 4 
 
The printed MAC address on the server board and/or server system is assigned to NIC1 on the 
server board. 
 
For security reasons, embedded LAN channels have the following default settings: 
  IP Address: Static 
  All users disabled 
IPMI-enabled network interfaces may not be placed on the same subnet. This includes the 
Intel
®
 Dedicated Server Management NIC
 
and either of the BMC’s embedded network 
interfaces. 
Host-BMC communication over the same physical LAN connection – also known as “loopback” 
– is not supported. This includes “ping” operations. 
On server boards with more than two onboard NIC ports, only the first two ports can be used as 
BMC LAN channels. The remaining ports have no BMC connectivity. 
Maximum bandwidth supported by BMC LAN channels are as follows: