Intel® Server Board S1400SP TPS 
Platform Management Functional Overview 
Revision 1.0 
 
 
Intel order number G64248-001 
67 
Three commands are implemented for SOL 2.0 configuration. 
  Get SOL 2.0 Configuration Parameters and Set SOL 2.0 Configuration Parameters: These 
commands are used to get and set the values of the SOL configuration parameters. The 
parameters are implemented on a per-channel basis.  
  Activating SOL: This command is not accepted by the BMC. It is sent by the BMC when 
SOL is activated to notify a remote client of the switch to SOL. 
  Activating a SOL session requires an existing IPMI-over-LAN session. If encryption is 
used, it should be negotiated when the IPMI-over LAN session is established.  
 
6.12.9 
Platform Event Filter (PEF)  
The BMC includes the ability to generate a selectable action, such as a system power-off or 
reset, when a match occurs to one of a configurable set of events. This capability is called 
Platform Event Filtering, or PEF. One of the available PEF actions is to trigger the BMC to send 
a LAN alert to one or more destinations.  
 
The BMC supports 20 PEF filters. The first twelve entries in the PEF filter table are pre-
configured (but may be changed by the user). The remaining entries are left blank, and may be 
configured by the user. 
Table 17. Factory Configured PEF Table Entries 
Event Filter 
Number 
Offset Mask 
Events 
Non-critical, critical and non-recoverable 
Temperature sensor out of range 
Non-critical, critical and non-recoverable 
Voltage sensor out of range 
Non-critical, critical and non-recoverable 
Fan failure 
General chassis intrusion 
Chassis intrusion (security violation) 
Failure and predictive failure 
Power supply failure 
Uncorrectable ECC 
BIOS 
POST error 
BIOS: POST code error 
FRB2 
Watchdog Timer expiration for FRB2 
Policy Correction Time 
Node Manager 
10 
Power down, power cycle, and reset 
Watchdog timer 
11 
OEM system boot event 
System restart (reboot) 
12 
Drive Failure, Predicted Failure 
Hot Swap Controller 
Additionally, the BMC supports the following PEF actions: 
  Power off 
  Power cycle 
  Reset 
  OEM action 
  Alerts 
The “Diagnostic interrupt” action is not supported. 
6.12.10  LAN Alerting  
The BMC supports sending embedded LAN alerts, called SNMP PET (Platform Event traps), 
and SMTP email alerts. 
The BMC supports a minimum of four LAN alert destinations.