Error
Display
Error Description
Action
88
Boiler  
overheating
Beverage dispenser temporarily blocked.
Check that mains tap is on or that the water 
tank is filled and correctly inserted
If subsequently no OK:
Switch off coffee machine
Clean brewing unit
See Customer Care Chapter, Cleaning, Brewing unit
Switch on and try again
(Release follows when cooled down to normal temperature).
Switch off coffee machine, allow to cool and 
switch on again

89
Boiler 
heat-up time fault
Switch machine off and on again.
161
Brewer water 
fault
Between each of the folloing steps switch the machine off and on 
again.  If fault not remedied carry out the next step.
Check that main tap is on or water tank  
correctly filled and inserted.
Clean brewing unit.
See Customer Care Chapter, Cleaning, Brewing unit
Set grind fineness one grade coarser.
See Other Settings chapter
Reduce Quality.
See Settings, Recipe.
163
Warm rinse water 
fault
Between each of the folloing steps switch the machine off and on 
again.  If fault not remedied carry out the next step.
Check that main tap on or water tank correctly 
filled and inserted
Clean brewing unit
See Customer Care Chapter, Cleaning, Brewing unit
186
Steam boiler level
Outlet temporarily blocked.
Check that coffee grounds container correctly 
inserted.
Switch machine off and on again.
188
Steam boiler 
overheating
Outlet temporarily blocked.
After releasing check milk foam and steam 
outlet.
Switch off machine, allow to cool and switch on 
again.
189
Steam boiler 
heat-up time 
failure
Switch machine off and on again.