SERVICE (cont.)
Removal and Replacement:
1.  Disconnect the wires from the rectifier.
.  Remove the #10-3 screw securing the rectifier 
to the motor mounting bracket.
3.  Remove the rectifier and discard.
4.  Install  new  rectifier  on  the  rear  of  the  motor 
mounting  bracket  and  secure  with  a  #10-3 
screw.
5.   Refer to Fig. 13 and reconnect the wires. 
BLK from Motor (+)
BLU to BLU from Motor (AC)
WHI from Main Harness (AC)
RED from Motor (-)
FIG. 13 RECTIFIER TERMINALS
P1381
RECTIFIER - G1MD ONLY