Bacharach PCA 3 Manual De Propietario
PCA
3 Manual
0024-9472 Rev 2
11
1.6. Features and Benefits
•
Powered by 4 ‘AA’ alkaline batteries or NiMH rechargeable batteries. An
optional AC adapter provides extended operation.
optional AC adapter provides extended operation.
•
O
2
and CO
LOW
measurement standard. Optional measurement of up to two
additional gases, including CO
HIGH
, NO, NO
2
, or SO
2
.
•
With the appropriate sensors installed, the analyzer optionally displays
pollution conversions for CO, NO, NO
pollution conversions for CO, NO, NO
2
, and SO
2
. Pollution conversions
include ppm, #/MBTU, mg/m
3
, and g/GJ.
•
B-Smart
®
sensor technology allows pre-calibrated sensors to be installed in
the field. Sensors are provided with data that can be entered through the
PCA
PCA
®
3 software, or instrument calibration menus, for easy calibration.
•
Automatic flushing of the CO
LOW
sensor with fresh air if the CO level
exceeds 4,000 ppm, thus protecting the CO
LOW
sensor from high CO levels.
To measure CO levels above 4,000 ppm, the analyzer automatically
switches to its CO
switches to its CO
HIGH
sensor, if installed.
•
Automatic purging of the gas-sample system if the detected gas levels are
abnormally high when the analyzer is turned OFF.
abnormally high when the analyzer is turned OFF.
•
Displays temperatures in either °F or °C
•
Displays pressure in either inwc, mb, Pa, or hPa
•
Backlit color graphic LCD with zoom capabilities
•
Low battery alarm
•
Stores 500 individual combustion records, which can later be recalled for
viewing, printing, or downloading to a personal computer. Stores an
additional 500 data logged records.
viewing, printing, or downloading to a personal computer. Stores an
additional 500 data logged records.
•
Wireless IrDA link for printing current and stored combustion records,
pressure records, calibration data, and diagnostic data
pressure records, calibration data, and diagnostic data
•
USB connectivity for downloading data to personal computer
•
Field replaceable sensors and thermocouple
•
Two year warranty on analyzer and all gas sensors except the O
2
sensor
which has a one (1) year warranty.
•
Language options including English, French, and Spanish
•
Custom Display Formats
•
Calibration Reminders: PCA
®
3 can be configured to remind the user that
calibration is past due.
•
Auto/manual zeroing option allows the operator to select the start-up mode.
Auto-zero determines the zero reading of the CO channel in fresh air and
provides an offset for the CO measurements. Also, all sensing channels are
automatically zeroed on ambient air when the analyzer is first turned ON.
Manual zero is used to detect CO that may be present during start-up.
Auto-zero determines the zero reading of the CO channel in fresh air and
provides an offset for the CO measurements. Also, all sensing channels are
automatically zeroed on ambient air when the analyzer is first turned ON.
Manual zero is used to detect CO that may be present during start-up.