Bacharach PCA 3 Manual De Propietario
PCA
3 Manual
0024-9472 Rev 2
37
NOTE: The date and time settings must be correct to get accurate
calibration reminders.
calibration reminders.
Figure 4-19. Selecting the Calibration Reminder Period
4.18. Run/Hold Screen Format
PCA
®
3 test data is located in the Run/Hold screen. By pressing the
RUN/HOLD
key, you should hear the pump running and see the word RUN at
the upper left hand corner of the display. The instrument is continuously
measuring and calculating the data that is shown in the Run/Hold screen. Press
the
measuring and calculating the data that is shown in the Run/Hold screen. Press
the
RUN/HOLD
key again, the pump should stop running and the word HOLD
should be shown at the upper-left hand corner of the display. The instrument will
now show the last measured and calculated data taken before the instrument
was placed in HOLD. Use the up and down arrow keys to scroll through the
complete list of measured and calculated values when the instrument is running
or in the hold mode. The default order in which data appears in the Run/Hold
screen is shown below.
now show the last measured and calculated data taken before the instrument
was placed in HOLD. Use the up and down arrow keys to scroll through the
complete list of measured and calculated values when the instrument is running
or in the hold mode. The default order in which data appears in the Run/Hold
screen is shown below.
O
2
Oxygen
CO
Carbon Monoxide
EFF
Combustion Efficiency
CO
2
Carbon Dioxide
T-STK
Stack Temperature
T-AIR
Ambient/Primary Air Temperature
EA
Excess Air
CO(#)
Carbon Monoxide content referenced to an Oxygen percentage
NO
Nitric Oxide
NO
2
Nitrogen Dioxide
NOx
Oxides of Nitrogen (NO and NO
2
combined)
SO
2
Sulfur Dioxide
NO(#)
Nitric Oxide content referenced to an Oxygen percentage
NO
2
(#)
Nitrogen Dioxide content referenced to an Oxygen percentage
NOx(#)
Oxides of Nitrogen content referenced to an Oxygen percentage
SO
2
(#)
Sulfur Dioxide content referenced to an Oxygen percentage