5.17.  Turning Off the Analyzer and Purging 
 
Turn OFF the analyzer by pressing the 
I/O
 button for at least 2
seconds, or until 
two beeps are heard. The unit will count down 5
seconds before shutting down, 
giving the operator an opportunity to keep the analyzer turned ON by pressing 
the 
RUN/HOLD
 button. 
 
If the PCA
®
3 was not purged with fresh air (as described in Ending a Combustion 
Test  on page 49), then the analyzer may remain ON with its pump running and 
display the message “PURGING SENSORS” as the result of combustion gases 
still being present inside the analyzer. At this time the operator should ensure 
that the probe is removed from the stack, allowing the analyzer to purge itself 
with fresh air. The 5-second shutdown sequence will not begin until the gas 
levels inside the analyzer drop below predetermined levels. 
 
 
NOTE:  Although not recommended,  the purging process can be 
bypassed by pressing the I/O button a second time.