Hoshizaki Modular Crescent Cuber KM-900MWF Manual De Usuario

Descargar
Página de 65
22
DIP SWITCH NO.
1
2
3
4
5
6
7
8
9
10
        KM-900MRF/3      OFF   OFF    ON      OFF    ON      ON
  OFF     OFF    OFF     ON
        KM-900MAF,        OFF   OFF    ON      OFF    ON      ON      OFF     OFF    OFF     ON
        KM-900MWF
[d] CONTROLS AND ADJUSTMENTS
The Dip Switch is factory-adjusted to the following positions:
Switch Nos. 1 and 2:
Used for adjustment of the Defrost Timer.
The Defrost Timer starts counting when the Thermistor reads a certain temperature
           at the Evaporator outlet.
Switch Nos. 3 and 4:
Used for adjustment of the Drain Timer.
When a freeze cycle is completed, the Pump Motor stops, and the icemaker
           resumes operation in 2 seconds.  Then the Pump Motor drains the Water Tank
           for the time determined by the Drain Timer.  The Drain Timer also determines the
           time to restrain completion of a defrost cycle, i.e. the minimum defrost time.
Switch Nos. 5 and 6:
 Used for adjustment of the Drain Counter.
 The Pump Motor drains the Water Tank at the frequency determined by the Drain
           Counter.
Switch Nos. 7 and 8:
            Used only for checking the Controller Board.  Usually set in OFF position.
Switch Nos. 9 and 10:
Used for adjustment of Freeze Timer.
The Freeze Timer determines maximum
freeze cycle time.  Upon termination of
Freeze Timer, machine initiates the
harvest cycle.  After 2 consecutive timer
terminations, machine will shut down,
possibly indicating a problem.