Chapter 1: Specifications
Table 1-1. CATx interconnect cable.
Cable Type
Description
CATx solid-core 24 AWG cable
This S/UTP (CAT5e) cable confoms to EIA/TIA-568-B.
Uses four pairs of 24 AWG wires. Connects according
to EIA/TIA-568-B (1000BASE-T).
Uses four pairs of 24 AWG wires. Connects according
to EIA/TIA-568-B (1000BASE-T).
CATx solid-core 26/8 AWG cable
This S/UTP (CAT5e) cable confoms to EIA/TIA-568-B.
Uses four pairs of 26/8 AWG wires. Connects according
to EIA/TIA-568-B (1000BASE-T).
Uses four pairs of 26/8 AWG wires. Connects according
to EIA/TIA-568-B (1000BASE-T).
NOTE: You can use use type 26/8 AWG flexible cables (patch cables), but the
maximum possible extension distance is cut in half.
Table 1-2. Maximum acceptable cable length.
Cable Type
Distance
CATx 24 AWG installation cable
400 ft. (140 m)
CATx 26/8 AWG patch cable
200 ft. (70 m)
1.2.2 Fiber
NOTE: A point-to-point connection is necessary. Operation with multiple patch
panels is allowed. Routing over active network components, such as
Ethernet hubs, ServSwitch DKM FXes, or routers, is not allowed.
Ethernet hubs, ServSwitch DKM FXes, or routers, is not allowed.
Type of Interconnect Cable
Table 1-3. Fiber interconnect cable.
Cable Type
Description
Single-mode, 9-µm
• Two fibers, 9-µm
• In-house patch cable (EFN092)
• In-house patch cable (EFN092)
Multimode 50-µm
• Two fibers, 50-µm
• In-house patch cable (EFN6020)
• In-house patch cable (EFN6020)
Multimode 62.5-µm
• Two fibers, 62.5-µm
• In-house patch cable (EFN116-LCLC)
• In-house patch cable (EFN116-LCLC)
NOTE: Only use single-mode cables for fiber connections that are based on 3G
SFPs.