Bionaire BSF1211C-MU - BSF1211C-MU Manual De Propietario

Descargar
Página de 2
P L E A S E   R E A D   A N D   S AV E   T H E S E
I M P O RTA N T   S A F E T Y   I N S T R U C T I O N S
F E AT U R E S   -   O P E R AT I O N S
Converting to a Table Fan
An additional short pole (Q) is supplied which allows the 
fan to be converted into a table fan (see Figure 2). To 
change to this short pole, remove the fan head assembly 
from its position on top of the inner pole extension (N) 
and unscrew the T-shaped locking lever (U) at the base. 
Remove the outer pole (P), replace with the short pole 
(Q) and reassemble as detailed above.
OPERATING INSTRUCTIONS
1.  Set fan base on a dry, level surface.
2.    Plug cord into any standard 120 volt AC outlet. 
Please make sure the Speed Control Knob is in the 
OFF (O) position. Speed Control Knob is located on 
the Fan Motor Housing.
3.  The SPEED is adjusted by turning the Speed Control 
Knob to the desired setting, O-3-2-1.
4.   The OSCILLATION control knob is located on the top 
of the Fan Motor Housing. To start Oscillation, push 
Control knob down. To stop Oscillation, pull Speed 
Control Knob up.
ADJUSTMENT INSTRUCTIONS
Tilt-Adjustment
Follow these instructions to tilt the Fan Head for upward 
angle air movement.
1.  To change the tilting angle of the fan head, simply 
loosen the tilt-adjustment knob (K).
2.  Move the fan head to the desired angle and firmly 
tighten the tilt-adjustment knob to lock into place.
Height Adjustment
Follow these instructions to adjust the height of the fan.
1.  Turn the pole locking knob (O) counter-clockwise to 
loosen the pole.
2.  Adjust the pole to the desired height and firmly 
tighten the locking knob in a clockwise direction.
CLEANING/MAINTENANCE INSTRUCTIONS
Follow these instructions to correctly and safely care for 
your fan. Please remember:
REPLACEABLE FUSE
If your (5 Amp, 125 Volt) replaceable fuse blows, please 
order a new fuse at 1-800-253-2764. Follow the below 
instructions to replace the fuse on the plug.
User Servicing Instructions
1.  Unplug your fan. Grasp plug and remove from the 
receptacle or other outlet device. Do not unplug by 
pulling on cord.
2.  Open fuse cover, located on the top of the plug, by 
using your thumb or a flathead screwdriver to slide 
the cover down towards the prongs. 
  
Note: Ensure that fuse cover is completely open 
before attempting to remove fuse.
3.  Remove fuse carefully by using a small screwdriver 
to pry the fuse out of the 
compartment by the metal 
ends of the fuse (see Fig. 3).
4.  Place plug on a solid, flat 
surface. Insert new 5 Amp, 
125 Volt fuse into fuse 
compartment and use a 
small screwdriver to secure 
the metal ends of the fuse 
into the compartment.
 
Caution: Risk of fire. Replace fuse only with 5 Amp, 
125 Volt fuse.
5.  Slide fuse cover closed completely. If fuse cover is 
difficult to close, make sure fuse is secured in place 
completely by pressing down on metal ends of the 
fuse.
6.  Risk of fire. Do not replace attachment plug. Contains 
a safety device (fuse) that should not be removed. 
Discard product if the attachment plug is damaged.
ASSEMBLY INSTRUCTIONS
Assembly Time: 10-15 minutes.
Tools Required: Phillips head screw driver.
NOTE: Make sure you remove all contents from the 
package. Please check packaging materials for parts that 
could be required to operate your fan.
Base/Pole Assembly
You will need the base cover (R), weight (S), outer pole 
(P), washer (T) and T-shaped locking lever (U).
1.  Turn the base cover upside down and place the 
weight into the base cover.
2.  Insert the threaded end of the T-shaped locking lever 
into the hole of the washer, weight and through the 
base cover.
3.  While holding the base cover and weight with one 
hand vertically, connect the outer pole to the base, 
sliding the T-shaped locking lever into the bottom of 
the outer pole with your other hand.
4.  Turn the T-shaped locking lever clockwise to securely 
attach the pole to the base.
5.  Set the base on the floor, weight side down.
Fan Head Assembly
You are now ready to assemble the fan head.
1.  Remove the protective sleeve (G) and unscrew grill 
mounting nut (D) by turning counter-clockwise from 
the motor shaft (F). Position the rear grill (E) over 
the motor shaft (F), making certain that the vertical 
slots at the top and bottom of the rear grill fit over 
the prongs on the motor housing (H). Make sure that 
the carry handle is topmost on the motor assembly.
2.  Secure the rear grill (E) in its place using the rear 
grill mounting nut (D). Turn this nut clockwise and 
tighten firmly. 
3.  Loosen the securing screw (C) on side of the fan 
blade (B) to slide the fan blade onto the motor shaft 
(F) through the rear protrusion. Make sure the 
securing screw (C) rest on the notch (flat side) of 
motor shaft and tighten the screw (C).  
CAUTION: Avoid contact with sharp end of blades.
4.  Centre the front grill (A) by aligning the Bionaire
®
 
logo on the logo plate so that it is horizontal and 
parallel with the floor. Then place the bracket at the 
top over the front and rear grills with the hole on the 
bracket going through the center vertical bar. Fasten 
the other clips, making sure they go over both the 
front and rear grills.
5.   Replace grill screw and nut (V) and tighten with screw 
driver.
Final Assembly
NOTE:
 The fan head locking knob (L) is attached with 
the additional short pole (Q) when shipped.
1.  Slide the inner pole extension (N) up from the outer 
pole (P), first loosening the pole locking knob (O), to 
securely hold this position. Tighten the pole locking 
knob (O).
2.  Place the fan head assembly into this extension pole, 
inserting the fan’s head neck (M) into the pole 
opening.
3.  Add the fan head locking knob (L) to the hole in the 
fan head's neck (M), making sure holes are aligned, 
and tighten.
When using electrical appliances, basic safety precautions 
should always be taken including the following:
1.  Read all instructions before using this appliance.
2.  Use fan only for purposes described in the instruction 
manual.
3.  To protect against electrical shock do not immerse 
unit, plug or cord in water or spray with liquids and 
plug the appliance directly into a 120V AC electrical 
outlet.
4.  Close supervision is necessary when any appliance is 
used by or near children.
5.  Unplug from outlet when not in use, when moving 
fan from one location to another, before putting on 
or taking off parts and before cleaning.
6.  Avoid contact with moving parts.
7.  Do not operate in the presence of explosive and/or 
flammable fumes.
8.  To avoid fire hazard, NEVER place the cord under 
rugs or any parts near an open flame, cooking or 
other heating appliance.
9.  Do not operate any appliance with a damaged cord 
or plug after the appliance malfunctions, or has been 
dropped/damaged in any manner. Discard fan or 
return to an authorized service facility for 
examination and/or repair.
10. Do not run cord under carpeting.  Do not cover cord 
with throw rugs, runner, or similar coverings.  Do not 
route cord under furniture or appliances.  Arrange 
cord away from traffic area and where it will not be 
tripped over. 
11. The use of attachments not recommended or sold by 
the appliance manufacturer may cause hazards.
12. Do not let the cord hang over the edge of a table, 
counter or come in contact with hot surfaces or leave 
exposed to high traffic areas. 
13. Do not use outdoors.
14. To disconnect, grip plug and pull from wall outlet. 
Never yank on cord.
15. Always use on a dry, level surface. 
16. Do not operate fan until fully assembled with all 
parts properly in place.
17. This product is intended for household use ONLY and 
not for commercial or industrial applications.
18. 
WARNING: To reduce the risk of electrical shock 
and injury to persons, do not use in window.
19. 
WARNING: To reduce the risk of fire or electric 
shock, do not use this fan with any solid-state speed 
control device.
20. This product employs overload protection (fuse). A 
blown fuse indicates an overload or short-circuit 
situation. If the fuse blows, unplug the product from 
the outlet. Replace the fuse as per the user servicing 
instructions (follow product marking for proper fuse 
rating) and check the product. If the replacement 
fuse blows, a short circuit may be present and the 
product should be discarded or returned to an 
authorized service facility for examination and/or 
repair.
PLEASE READ AND SAVE 
THESE IMPORTANT SAFETY 
INSTRUCTIONS
F E AT U R E S   -   O P E R AT I O N S
C L E A N I N G / M A I N T E N A N C E
THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the 
other). To reduce the risk of electric shock, this plug is intended to fit in 
a polarized outlet only one way. If the plug does not fit fully in the 
outlet, reverse the plug. If it still does not fit, contact a qualified 
electrician to install the proper outlet. 
DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS 
SAFETY FEATURE IN ANY WAY.
Fuse cover
Fig. 3
Metal ends
Fuse
A
Fig. 1
B
C D
E
F
V
G H
I
M
O
P
Q
R
S
T
U
J
K
N
L
A  Front Grill
B.  Fan Blade
C.  Securing Screw
D.  Grill Mounting Nut
E.  Rear Grill
F.  Motor Shaft
G.  Plastic Sleeve
H.  Motor Housing
I.  Speed Control Knob
J.  Oscillation Control Knob
K.  Tilt Adjustment Knob
L.  Fan Head Locking Knob
M.  Fan Head's Neck
N.  Inner Pole Extension
O.  Pole Locking Knob
P.  Outer Pole
Q.  Additional Short Pole
R.  Base Cover
S.  Weight
T.  Washer
U.  T-Shaped Locking 
Lever
V.  Grill Screw and Nut
Base Cover
Additional Short Pole
Fig. 2
BSF1211C-MU_12EM1.indd   2
10/12/12   11:13 AM