Bunn Beverage Dispenser AF PR-3 Manual De Usuario

Descargar
Página de 17
6
PROBLEM
1. Empty product container
2. No power or incorrect voltage to 
the dispenser
3. Signal cable unplugged
4. Hopper is full
5. Fuse and fuse holder
6. Main ON/OFF switch
7. Probe box LOW/OFF/HIGH switch-
es 
8. Circuit board
9. Vacuum switches
10. Vacuum/Supply pump
1. Motor over heats
Replace or refill
(A1) Check the outlet for 120 volts 
on two wire 120 volt dispenser.
(A2) Check the outlet for 200 volts 
or 240 volts ac for two wire 200 volt 
or 240 volt dispensers.
(B) Check circuit breakers or fuses.
Signal cable must be plugged in.
Product must not be touching probes 
to fill.
Refer to Service - Fuse and Fuse 
Holder for test procedures. See 
page 8
Refer to Service - Main ON/OFF 
Switch for testing procedure. See 
page 9  
Refer to Service - Probe System. 
See page 10
Refer to Service - Circuit Board for 
testing procedures. See page 7
Refer to Service - Vacuum Switches 
for testing procedures. See page 14
Refer to Service  - Vacuum/ Supply 
Pump for testing procedures. See 
page 12
The thermal switch will reset, but 
requires up to 30 minutes of cooling 
time. See NOTE below.
TROUBLESHOOTING (cont.)
28791.1 011500
Product will not dispense
PROBABLE CAUSE
REMEDY
Motor thermal cutout (motor stops 
running)
NOTE: This refill unit should not be used to initially fill the hopper. Running the motor for extended periods will 
trip the thermal switch. The thermal switch will reset, but requires up to 30 minutes of cooling time.