4
Technical data
Exposure meter
Measuring modes
Ambient light
Incident light method
Reflected light 
method
Contrast measurem.
Light sensor
sbc photo diode
Measuring range
(when ISO 100/21°)
EV 0 to 18
Shutter speeds
1/2000 s to 4 min 
Apertures
1 to 32
Calibration 
adjustments
± 3.0
Film speeds
ISO 6 to 3200 
in 1/3 increments
Measuring angle 
reflected light mode
approx. 25°
Timer
0 sec to 30 min
Watch
adjustable to 12 hrs 
(AM + PM) or 24 hrs
Accuracy
5 min / year
Thermometer
adjustable to °C/ °F
Measuring range
–15 ... 70 °C or 
5 ... 160 °F
Accuracy
± 2 °C or ± 4 °F
Display
digital read-out of 
measuring value 
plus analogue 
setting ring
Duration of read-out The DS will always 
display the last 
function used