6-4
SOURCE OUTPUT
ACCURACY
This test verifies the source output accuracy of the MS462XC. The test
procedure uses the Power ALC Verification built-in function of the
MS462XC Basic Measurement software.
Setup:
Step 1.
Connect a GPIB cable between the power meter GPIB connec-
tor and the MS462XC dedicated GPIB connector, as shown in
Figure 6-1.
Step 2.
Turn on the MS462XC VNMS and allow it to warm-up at
least one hour.
Test Procedure
Step 1.
Disconnect cables between MS462XC
Port 1
and
Port
1 of
MS4782 Test Set and between
Port 3
of MS462XC and
Port 3
of MS4782 Test Set.
Step 2.
Press
Utility
key and select:
DIAGNOSTICS
TROUBLESHOOTING
MORE
VERIFY ALC CALIBRATON
Step 3.
Calibrate and zero the power sensor.
SOURCE OUTPUT ACCURACY
PERFORMANCE VERIFICATION
6-2
ME 7840A OMM
Noise
In
Noise
+28V
NO OPERATOR SERVICE-
ABLE PARTS INSIDE.
REFER SERVICING TO
QUALIFIED PERSONNEL.
WARNING
CAUTION
FOR CONTINUED FIRE
PROTECTION REPLACE
ONLY WITH SPECIFIED
TYPE AND RATED FUSE.
IEEE 488.2
GPIB
Dedicated
GPIB
Serial Port
Ethernet
VGA
SCSI-2
Ext
Analog
Output
Ext
Trigger
LPT Line Printer
Ext I/O
Port 1
Port 2
Bias
Bias
Port 2
Bias Fuse
Port 1
Bias Fuse
Ext Analog
In
Ext
Source
Ext 10 MHz
In
47-440 Hz
85-264VAC
REPLACE FUSE ONLY WITH
SAME TYPE AND RATING
CAUTION
DO NOT OPERATE
WITH POWER CORD
UNGROUNDED
N274
00000001
Made in UK
12-24V DC
(1.3A)
OUTPUT 1
OUTPUT 2
INPUT 1
DIGITAL
INPUT 2
ANALOG
CALIBRATOR
B
RS 232
PARALLEL PRINTER
GPIB / IEEE 488
CAUTION
DO NOT OPERATE
WITH UNGROUNDED
POWER CORD.
85-250 VAC
47-440Hz
40VA MAX
SEE MANUAL FOR VOLTAGE RANGES ON BNC CONNECTORS
A
NO OPERATOR SERVICE-
ABLE PARTS INSIDE.
WARNING
Figure 6-1. ML2430A Series Power Meter GPIB connection to the MS462XX Vector Network Measurement System