Brocade Communications Systems Switch 53-1001762-01 Manual De Usuario

Descargar
Página de 252
Converged Enhanced Ethernet Command Reference
183
53-1001762-01
DRAFT: BROCADE CONFIDENTIAL
Chapter
11
RMON Commands
rmon alarm
Sets alarm conditions. 
Synopsis
rmon alarm index snmp_oid interval seconds {absolute | delta} rising-threshold value event 
number [falling-threshold value event number [owner name] | owner name]
no rmon alarm index [snmp_oid interval seconds {absolute | delta} rising-threshold value event 
number [falling-threshold value event number [owner name] | owner name]]
Operands
index
Specifies the alarm index. The range of valid values is 1-65535.
snmp_oid
Specifies the MIB object to monitor. The variable must be in the SNMP OID 
format, for example, 1.3.6.1.2.1.16.1.1.1.5.65535. The object type must be a 
counter32.
interval seconds 
Specifies the alarm sample interval in seconds. The range of valid values is 
1-2147483648.
absolute
Sets the sample type as absolute.
delta
Sets the sample type as delta.
rising-threshold value 
Specifies the alarm rising threshold. The range of valid values is 
0-4294967295.
event number
Specifies the event for the rising alarm. The range of valid values is 1-65535.
falling-threshold value
Specifies the alarm falling threshold. The range of valid values is 
0-4294967295.
event number
Specifies the event for the rising alarm. The range of valid values is 1-65535.
owner name
Specifies the identity of the owner. The maximum number of characters is 32.
Defaults
There are no alarms configured.
Command
Modes
Global configuration mode
Description
Use this command to set alarm conditions. Use the no rmon alarm command to disable the alarm 
conditions.
Usage
Guidelines
There are no usage guidelines for this command.
Examples
To set alarm conditions: