BEHRINGER DEQ2496 QUICK START GUIDE 
 
The ULTRACURVE PRO DEQ2496 is an ultra high-precision digital 24-bit/96 kHz EQ/RTA mastering 
processor. Its extremely high audio performance makes it ideal for audiophile mastering and PA 
purposes. There are 4 concurrently selectable EQ modules (31-band graphic EQ, 10-band parametric EQ, 
Feedback Destroyer and three dynamic EQs p
er channel).
 
 
 
How to reset the DEQ2496 to Factory Default condition: 
• 
Hold down the MEMORY and COMPARE buttons while powering up the DEQ2496 
• 
Press the B button to confirm the reset 
 
Accessing the AUTO-EQ function: 
• 
Press the RTA button several times until page 1 of the RTA menu is displayed 
• 
Press the B button (next to the “AUTO EQ” indicator in the left-hand side of the display) 
• 
Turning the Data Wheels will now adjust the target EQ curve that you want to achieve 
• 
Press the PAGE button to advance to page 2 of the AEQ menu 
• 
Press the A button (next to the “START AUTOEQ” indicator in the left-hand side of the display) to start the Auto-EQ 
process 
• 
Press the A button again to stop the process 
• 
Page the PAGE button to advance to page 3 of the AEQ menu  
• 
Press the B button (next to the “DONE” indicator in the left-hand side of the display) to exit Auto-EQ mode  
 
Using the Graphic Equalizer function on the DEQ2496: 
• 
Press the GEQ button to display the GEQ menu 
• 
Turn the small Upper Data Wheel to select the frequency to work with 
• 
Turn the small Lower Data Wheel to select the bandwidth you want to affect 
• 
Turn the Large Data Wheel to adjust the GAIN of the frequency 
• 
For each control you will see visual feedback from the curve in the middle of the display and the numbers on the right 
of the display 
 
Using the Parametric Equalizer function on the DEQ2496: 
• 
Press the PEQ button several times to display page 1 of the PEQ menu 
• 
Turn the mall Upper Data Wheel to select the frequency to work with 
• 
Turn the small Lower Data Wheel to select the bandwidth you want to affect 
• 
Turn the large Data Wheel to adjust the GAIN of the frequency 
• 
For each control you will see visual feedback from the curve in the middle of the display and the numbers on the right 
of the display 
 
Accessing the Limiter function on the DEQ2496: 
• 
power-up the DEQ2496 
• 
press the DYN button several times until PAGE 2 of the DYN menu is displayed 
• 
press the B button  (next to the "LIMITER" indicator in the left-hand side of the display)  
• 
use the Data Wheels to the right of the display to adjust the parameters 
 
Accessing the Compressor/Expander function on the DEQ2496: 
• 
press the DYN button several times until PAGE 1 of the DYN menu is displayed 
• 
press the B button  to switch between expander and compressor functions  
• 
use the Data Wheels to the right of the display to adjust the parameters 
 
Accessing the Stereo Imager function on the DEQ2496: 
• 
press the WIDTH  button several times until PAGE 1 of the WIDTH menu is displayed 
• 
use the Data Wheels to the right of the display to adjust the parameters 
 
Accessing the Stereo Delay for delay line applications on the DEQ2496: 
• 
press the I/O  button several times until PAGE 4 of the I/O menu is displayed 
• 
use the Data Wheels to the right of the display to adjust the parameters 
 
Accessing the different Metering displays on the DEQ2496: 
• 
Press the METER button 
• 
Press the METER button or the PAGE button to cycle through the three different meters (peak/RMS, SPL, VU) 
 
Using the Module Bypass function on the DEQ2496: 
• 
Press the BYP button 
• 
Use the Large Data Wheel to select a module to bypass 
• 
Press the B button to bypass the module 
• 
Pressing the B button again will re-enable that module