EUROLIGHT  LC2412
uses this standard (even if it is done with partially different plug-
in connectors), your EUROLIGHT LC2412 is therefore extremely
flexible in how it can be implemented.
A big advantage of digital control is its enourmously simplified
cabling,  since  you  only  need  one  single  cable  for  transmitting
control  data.  This  sets  the  DMX system  apart  from  its  analog
conterparts, which need an extra control cable for each individual
channel. Another big advantage is made possible by the freely
addressable  receivers,  which  is  done  by  menas  of  software.
You  can  therefore  save  yourself  from  having  to  painstakingly
lay cables each time you wish to assign a particular dimmer to a
different channel. Additional information on this subject can be
found in chapter 8.2.2.
Interface  format  (EIA-485)
The DMX512 standard uses the RS485 interface standard for
data  transmission,  well-known  for  its  impunity  to  interferrence.
The data are serially transmitted in the asynchron fashion at a
transmission  rate  of  250  kBit/s,  successively  for  each  of  the
connected dimmers (up to 512 channels). The more dimmers are
connected, the longer the time interval until the next command on
this channel.
+
It  is  advisable  to  limit  the  number  of  deployed
channels  in  order  to  ensure  a  maximum  refresh
rate.  Therefore,  do  not  use  more  channels  than
you  actually  need.
In combination with the DMX512 standard, you can run up to
32 loads on a single sender (LC2412). One load responds to one
DMX512/RS485 receiver, for example, the way it is implemented
in a dimmer pack.
If you wish to run more than 32 loads, we recommend using
level translaters and/or signal splitters.
8.2.2 Assigning DMX channels (softpatch)
Softpatch means: you can assign up to three freely selectable
DMX channels to a console channel.
+
Each  of  the  DMX  channels  can  be  assigned  to  only
one  fader.  Otherwise,  contradicting  commands
would  be  given  with  various  fader  settings.
To  make  the  capabilities  of  the  DMX512  as  well  as  the
capabilities of the LC2412 transparent, we have to draw a clear
distinction  between  three  different  kinds  of  channels:
Console  channels
The channels of your LC2412 (= 24+2 channels) are 26 routes
through which you can send commands. This in no way means
that you can only control 24 lighting elements.
Dimmer  channels  (dimmer  loops)
Dimmer packs represent the power section of a light control
system, comparable to power amplifiers of a PA installation in
the audio field. Each dimmer channel is assigned to one DMX
channel, that is, it can receive commands from only one channel.
For example, if a dimmer loop can handle a maximum power
rating  of  2.3  kW,  you  can  connect  several  lamps,  spotlights
and similar (e.g. 4 x 500 W).
DMX  channels
A  DMX  channel  consists  out  of  one  digitally  transmitted
information unit (1 Byte/8 Bit), whereas 256 different information
units can be transmitted. These units are transmitted sequentially,
that is, channels 0 and upwards on the sender are accounted
for,  and  the  respective  information  units  are  assigned.  The
sequence  then  starts  anew  at  the  next  channel.  In  the  worst-
case scenario (all 512 channels are in use) the refresh rate has
the value of 44.1 Hz. You can derive from this that it is advisable
to only use as many channels as you actually need.
Since  there  are  24  channels  with  adjustable  illumination  (to
each of which 3 DMX channels can be assigned), there is a total
of 72 DMX channels that can be laid out. Additionally, there are
two special channels, each of which can switch a maximum of
2 DMX channels on and off.
To  assign  the  desired  DMX  channels  to  individual  console
channels (or to preview the assignment of channels), go through
the  following  steps:
1. Press the UTILITY 2 key.
Fig. 8.2: Display “DMX Patch 1”
2. Select “DMX PATCH” using the SOFT A key.
Fig. 8.3: Display “DMX Patch 2”
The  console  channel  is  shown  in  the  top  left  portion  of  the
menu.  The  connected  DMX  channels  are  shown  to  its  right
(standard  setting  is  1:1.  Example:  Console  channel  01  is
connected to DMX channel 000, console channel 08 is connected
to DMX channel 07, etc.).
The DMX channel is shown in the lower left line; its status is
shown next to it (NU = Not Used or USE 1...512). In our example
DMX channel 000 is connected to console channel 01.
3. Use the Flash keys to first select the console channel to
which you wish to assign a DMX channel (channels13 - 24:
switch to upper mode, SPECIAL 1 (channel 25) and SPECIAL 2
(channel 26) by pressing 
 and 
).
4. Select a DMX channel usign the DATA  wheel.
If this DMX channel is already occupied, this will be shown in
the  display  together  with  the  respective  console  channel
number. Select the console channel (FLASH key), and select
“OPEN” (SOFT B key). Start again at step 3. Alternatively,
you can also select a different DMX channel.
5. Press the SOFT A key (“CONNECT” option) and connect the
console channel with the DMX channel. If you wish to connect
multiple DMX channels with the same console channel, simply
select  an  additional  DMX  channel  and  proceed  with  the
connection  as  previously  described.
6. Use the QUIT key to go back to the main menu.
Connecting  channels  1:1  (one-to-one)  or  disengaging  all
connections
1. Perform steps 1 and 2, as described under 8.2.3.
2. Press the SHIFT key 
.
Fig. 8.4: Display “DMX Patch 3”
3. Now, select “ALL CLEAR” using the SOFT B key to disengage
all  connections.  Use  SOFT  A  to  go  back  to  the  standard
setting,  “ALL  1:1.”
9. INSTALLATION
You will need various types of cables for different applications.
The following illustrations show you how to lay out these cables.
Always  use  only  high-grade  cables.
9. INSTALLATION