INSTALLATION
 WIRING
 
The Group 14 drive is available with six 
separate control configurations which are 
provided to match the control requirements 
for your system.  Typical functional wiring 
connections for each control option are described 
in the following paragraphs and diagrams.  The 
wiring diagram specific to each drive is attached 
to the inside of the wiring terminal cover.
 
Feedback connections for drives incorpor-
ating the Contactless Position Sensor (CPS-2) 
for control options 6 and 8 are described on 
pages 13 and 14.
 
A Group 14 drive can be ordered with up 
to four optional auxiliary switches.  Wiring 
connections for these are described on page 22.
Option 8, Modulating
Analog Position Control with
Contactless Position Sensing
 
Customer must supply two wires to power the 
drive:  One 120 V ac line (terminal C), and one 
neutral (terminal B).  Customer must supply two 
wires for the modulating analog control signal: 
Connect to terminal AA (+) and to terminal BB(-).  
Customer may supply two additional wires to 
monitor the analog position feedback signal (see 
pages 13 and 14 for connections).  The drive’s 
feedback circuit power supply is derived from the 
120 V ac line, therefore the feedback signal must 
be wired to a “4-wire” type non-powered analog 
input.
 
To enable full Handswitch operation, connect 
a 120 V ac line to terminal C (jumper between 
terminals A and C).  
Figure 2
 
The wiring diagram at 
right is a typical example 
of an Option 8 drive with 
a Stall Protection Module 
installed.