Bunn PAF (Ultra) Manual De Propietario

Descargar
Página de 7
3
INTRODUCTION
This equipment supplies a liquid mix to the  hoppers on the ULTRA-2 dispenser.  It is for indoor use only on a 
sturdy counter or shelf.
00656.0001
00986.0000
USER NOTICES
Carefully read and follow all notices on the equipment and in this manual.  They were written for your protection. 
All notices are to be kept in good condition.  Replace any unreadable or damaged labels.
As directed in the International Plumbing Code of the 
International Code Council and the Food Code 
Manual of the Food and Drug Administration (FDA), 
this equipment must be installed with adequate 
backflow prevention to comply with federal, state 
and local codes. For models installed outside the 
U.S.A., you must comply with the applicable Plumb-
ing /Sanitation Code for your area.
Artwork for P/N:  00656.0001
Artwork Rev:  A
Drawn:  REF
Date:  04/22/10
INITIAL SET-UP
1. 
Loosen auger motor cover screws.
2. 
Remove rear plastic plug from trim strip between hopper drip trays.
3. 
Install support rod into hole in trim strip.
4. 
Place PAF platform assembly on top of motor covers.
5. 
Tighten support rod from top of platform.
6. 
Retighten motor cover screws.
7. 
Plug RCA cord into ULTRA base unit.
8. 
Install hopper seal and press firmly into place on the flange of the cooling drum.
9.  Align the auger shaft with the flat fin of the auger. Push the augers as far as they will go and rotate them 
so the flat fin is facing up.
10.  Place level probes in notch in rim of hoppers and install hoppers.
10.  Install PAF units onto hoppers and platform.
11.  Plug PAF power cord into rear of platform.
12.  Plug PAF platform power cord into proper electrical outlet.
13.  Attach a flexible water line to the .25” flare fitting on the back panel of the Powder Auto-Fill.
NOTE: A water strainer assembly (BUNN-O-MATIC #23820.1000) should be installed in line prior to the flexible 
water line.
29793.1 081511
Push back until fully latched
before removing or manually
filling chilled product hopper.
34561.0000
NOTE - Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed 
and maintained in accordance with federal, state and local codes.
37881.0000
00824.0002