White Rodgers F145-1328 Wired Indoor Remote Sensor Instruccion De Instalación

Descargar
Página de 8
F145-1328/F145-1378
Indoor Remote Sensor/Outdoor Remote Sensor
INSTALLATION INSTRUCTIONS
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY 
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE 
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
 
 SPECIFICATIONS
CAUTION
!
To prevent electrical shock and/or equipment 
damage, disconnect electric power to system 
at main fuse or circuit breaker box until instal-
lation is complete.
WARNING
!
Do  not  use  on  circuits  exceeding  specified 
voltage.  Higher voltage will damage control 
and could cause shock or fire hazard.
Do not short out terminals on gas valve or prima-
ry control to test.  Short or incorrect wiring will 
damage thermostat and could cause personal 
injury and/or property damage.
For applications where the wire run is short (
100 ft. 
or less) shielded cable may not be required provided 
the wires are not routed parallel to or across other 
wires carrying electrical power. To reduce electrical 
interference or inductance from other electrical wir-
ing or devices use shielded cable and keep Remote 
Sensor wire runs separate from thermostat wiring. 
Remote sensors cannot be used with systems where 
power interruptions are part of normal system op-
eration. Compatible with all White-Rodgers remote 
sensing thermostats.
Operating Range: (based on thermostat range)
F145-1328 Indoor Model: 40 to 99°F
F145-1378 Outdoor Model: -40 to 140°F
Operating Humidity Range: 
0  to 90% RH 
(non-condensing)
Maximum Distance from Thermostat
300 feet
Recommended Wire: 
18 or 20 gauge,    
3-conductor shielded cable
Color: Classic White
Dimension: 
2 1/8" x 3 1/2" x 3/4" 
Outdoor Remote includes
 12 ft. of outdoor 
probe lead
F145-1328
INDOOR REMOTE SENSOR
F145-1378
OUTDOOR REMOTE SENSOR
Interior Mounting Base
Outdoor Probe
CONTENTS
Specifications ................................................ 
1
Installation .................................................... 
2
Remote Sensor Terminal Cross Reference ...... 
2
Wiring F145-1328 (Single Stage) .....................3
Wiring F145-1328, F145-1378 (Multi-Stage) ... 3
Wiring 
1F97-1277 (Blue Touchscreen) .............4 
Wiring 
1F95-1277 (Blue Touchscreen) ............ 4
Configuration .................................................
Remote Sensor Calculated Priority Average .....5
Maximum Sensing Locations 
  Per Thermostat (Chart) ..................................6
Troubleshooting ...............................................7
PART NO. 
37-6606C
Replaces 37-6606B
1319
www.white-rodgers.com
www.emersonclimate.com