Brocade Communications Systems Brocade Backbone DCX 8510-4 Manual De Usuario

Descargar
Página de 168
134
Brocade DCX 8510-4 Backbone Hardware Reference Manual
53-1002177-05
Obtaining chassis and component status
C
Obtaining chassis and component status
The CLI commands in 
 provide status and environmental information about the chassis 
and its components. These commands provide information only, and they do not interrupt traffic 
flow. For more information about these commands, refer to the Fabric OS Command Reference.
Interpreting POST and boot results
The Brocade DCX 8510-4 performs Power On Self Test (POST) by default each time the chassis is 
powered on, rebooted, or reset. The Brocade DCX 8510-4 can be rebooted using the reboot (to 
reboot each CP individually) or fastBoot commands. The fastBoot command reboots the switches 
without running POST. If the active CP blade is rebooted, it fails over to the standby CP blade.
POST
The Brocade DCX 8510-4 automatically performs POST each time it is powered on or reset.
To verify that POST has completed without error:
Verify that all LEDs return to a normal state after POST completes.
If one or more LEDs do not return to a normal state, and this is not due to the Brocade DCX 
8510-4 being set to beacon, refer to the relevant LED table to identify and correct the problem. 
For port blades, and CP and core switch blades, the slotShow command can be used to check 
the status of the slots. For information about turning beaconing on/off, refer to the Fabric OS 
Administrator’s Guide
.
Verify that the switch prompt displays when POST completes.
If it does not display, POST was not successfully completed. Contact the Brocade DCX 8510-4 
supplier for support.
TABLE 25
Environmental status and maintenance commands
Command
Information displayed
sensorShow
Temperature readings for the port blades
Temperature readings for the CP blades
Status and RPM of all operational fans
Status of all operational power supplies
tempShow
Temperature readings for the port blades
Temperature readings for the CP blades
psShow
Status of all operational power supplies
fanShow
Status and RPM of all operational fans
chassisShow
Serial number, time awake, and additional information about each component
slotShow
Slot occupancy
errShow
errDump
System error log. Refer to the Fabric OS Message Reference for more information on the 
messages in this log.