Brocade DCX 8510-4 Backbone Hardware Reference Manual
55
53-1002177-05
Determining the status of a WWN card
4
FIGURE 16
Blower assembly
 describes the LED patterns for the blower assembly.
Determining the status of a WWN card
Complete the following steps to determine the status of a WWN card.
1
Power  LED
2
Fault  LED
TABLE 7
Blower assembly LED descriptions
LED purpose
Color
Status
Recommended action
Power
No light 
(LED is off)
Blower assembly does not 
have power.
Ensure that the blower assembly 
is firmly seated and has power.
Steady green
Blower assembly has 
power. 
No action required.
Fault
No light 
(LED is off)
Blower assembly is either 
healthy or does not have 
power.
Ensure that the blower assembly 
has power.
Steady amber 
Blower assembly has a 
failure (full or partial).
Replace the blower assembly.
Slow-flashing amber
(on 2 sec, then off 2 sec)
Blower assembly is not 
seated correctly or is 
faulty.
Pull the unit out and reseat it. If 
the LED continues to flash, 
replace the unit.
Flashing amber
(on 1/2 sec, then off 3.5 sec)
Fan is disabled.
Run the fanEnable command to 
enable the fan.
Fast-flashing amber
(on 1/2 sec, then off 1/2 sec)
Environmental range 
exceeded.
Check for out-of-bounds 
environmental condition, resolve 
any problems, and reseat the 
unit. If the LED continues to flash, 
replace the unit.
1