Control processor blade (CP8) removal and replacement
5
bring both blades to the same firmware version. Once you have installed the replacement CP 
blade, see 
 for information about determining the 
version of firmware on the replacement CP blade and upgrading it if necessary.
For this procedure, please refer to 
Complete the following steps to remove a CP8 control blade (CP).
1. Open the ejector handles to approximately 45 degrees. Orient the CP blade so that the handles 
are toward you and the flat metal side is on your left.
2. Align the flat metal side of the CP blade inside the left and right blade guides in the slot. Slide 
the CP blade into the slot until it is firmly seated.
3. Tighten the thumb screw inside each handle using the Phillips screwdriver.
4. Turn the CP blade on by sliding the ON/OFF switch in the left handle to the left, to cover the 
thumb screw.
5. Verify that the power LED is green. If not, ensure that the CP blade has power and is firmly 
seated and that the ejectors are in the locked position. 
6. Connect the cables to the new CP blade.
7. Remain logged in to the active CP and continue to “Verifying operation of the new CP blade.”
Verifying operation of the new CP blade
To verify that boot and POST are complete on the new CP blade and that the CP blade has achieved 
failover redundancy, perform the following steps.
1. Type slotShow. The command output shows the new CP blade as “enabled.”
If the standby CP is unresponsive, you can try unplugging the new CP blade, running haDisable 
on the active CP blade, and plugging the new CP blade back in. At that point, you can repeat 
step 1 above to begin the verification process again.
2. Determine the version by entering firmwareShow. If the serial console on the replacement CP 
blade is connected, issue the firmwareShow command there. More information is available 
through the console.
NOTE
The DCX 8510-4 requires Fabric OS 7.0.0 or later to be recognized. If the firmware on the 
replacement blade is earlier than 7.0.0 it must be brought up to the version on the active CP 
blade, which must be at least 7.0.0.
3. If the firmware versions for both CP blades are the same, skip to “Complete the replacement.”
If the firmware version on the replacement blade does not match that on the active CP blade, a 
warning message appears with the results of the firmwareshow command. The results of the 
firmwareshow command may look similar to the following. Note the warning message at the 
end of the output.
DCX_xyz:admin> firmwareshow
Slot Name     Appl     Primary/Secondary Versions               Status
------------------------------------------------------------------------
  4 CP0      FOS      v7.0.0
 ACTIVE