TROUBLESHOOTING 
 
Problem 
Possible Causes 
Solutions 
The portable air 
conditioner does not 
turn on 
  Power failure / outage. 
 
  The automatic switch, line 
fuse, or breaker has been 
tripped. 
 
 
 
  The power supply voltage is 
too low. 
 
  The power cord is damaged. 
 
 
 
  The L.C.D.I. power plug for 
the unit is tripped. 
  The internal water reservoir 
is full. 
  Possible loose connection 
  Internal fuse has blown 
 
  Restore the power supply. 
 
  Flip the switch / change the fuse / turn the breaker 
back on. Also note that you may have too many 
appliances drawing power on one circuit, you may 
need to move the other appliances to another 
circuit. 
 
  Move the unit onto another circuit with the correct 
voltage. 
 
  Contact Whynter Service Department. Only 
authorized personnel should replace damaged 
power cord or power plug. 
 
  Press the Reset button on the L.C.D.I. power plug. 
 
  Drain water from the air conditioner. 
 
  Contact Whynter Service Department 
The unit turns on but 
the compressor does 
not turn on (the fan 
runs but the unit is not 
cooling) 
  The room temperature is 
outside of the operational 
tolerances of the unit. 
 
  The Cooling mode is not on. 
 
 
  The compressor has not 
turned on yet because of its 
time delay. 
 
  The set temperature is too 
high. 
 
 
  The internal water reservoir 
is full. 
  This unit is designed to work in ambient 
temperatures of 64°F to 95°F. 
 
 
  Press the MODE button until the COOL light is 
shown on the display. 
 
  Give the compressor 3 minutes to turn on after the 
Cooling mode has been selected. 
 
 
  Set the air conditioner to a lower temperature. It is 
recommended to set the temperature to at least 
5°F of the ambient temperature. 
 
  Either manually drain the water by removing the 
drain plug or allow the unit to exhaust the water 
itself by running the fan only mode. Then cooling 
will resume.