Symptom
Possible Cause
Corrective Action
No Heat/No Cool/No Fan 
(common problems)
1. Blown fuse or tripped circuit breaker. 
2. Furnace power switch to OFF. 
3. Furnace blower compartment door or 
  panel loose or not properly installed. 
4. Loose connection to thermostat or system.
Replace fuse or reset breaker. 
Turn switch to ON. 
Replace door panel in proper position to engage safety 
interlock or door switch. 
Tighten connections.
No Heat
1. Pilot light not lit. 
2. Furnace Lock-Out Condition. Heat 
  may also be intermittent. 
 
 
3. Heating system requires service or 
  thermostat requires replacement. 
Re-light pilot. 
Many furnaces have safety devices that shut down when 
a lock-out condition occurs. If the heat works intermittently 
contact the furnace manufacturer or local HVAC service 
person for assistance. 
Diagnostic: Set SYSTEM Switch to HEAT and raise the 
setpoint above room temperature. Within a few seconds 
the thermostat should make a soft click sound. This sound 
usually indicates the thermostat is operating properly. If 
the thermostat does not click, try the reset operation listed 
above. If the thermostat does not click after being reset 
contact your heating and cooling service person or place 
of purchase for a replacement. If the thermostat clicks, 
contact the furnace manufacturer or a HVAC service 
person to verify the heating is operating correctly.
No Cool                                         
1. Cooling system requires service or 
  thermostat requires replacement.
Same as diagnostic for No Heat condition except set the 
thermostat to 
COOL and lower the setpoint below the 
room temperature. There may be up to a five minute delay 
before the thermostat clicks in Cooling.
Heat, Cool or Fan 
Runs Constantly
1. Possible short in wiring. 
2. Possible short in thermostat. 
3. Possible short in heat/cool/fan system. 
4. FAN Switch set to Fan 
ON.
Check each wire connection to verify they are not shorted 
or touching together. No bare wire should stick out from 
under terminal block. Try resetting the thermostat as de-
scribed above. If the condition persists the manufacturer 
of your system or service person can instruct you on how 
to test the Heat/Cool system for correct operation. If the 
system operates correctly, replace the thermostat.
Thermostat Setting & 
Thermostat Thermometer 
Disagree
1. Thermostat thermometer setting 
  requires adjustment.
The thermometer can be adjusted +/- 4 degrees. See 
Temperature Display Adjustment in the Configuration 
Menu section.
Furnace (Air Conditioner) 
Cycles Too Fast or Too Slow 
(narrow or wide  
temperature swing) 
1. The location of the thermostat and/or 
  the size of the Heating System may 
  be influencing the cycle rate.
Digital thermostats provide precise control and cycle 
faster than older mechanical models. The system turns 
on and off more frequently but runs for a shorter time 
so there is no increase in energy use. If you would like 
an increased cycle time, choose 
SL for slow cycle in the 
Configuration menu, step 7 (heat) or 8 (cool). If an ac-
ceptable cycle rate is not achieved, contact a local HVAC 
service person for additional suggestions. 
Forgot Keypad 
Lockout Code
Press the menu 
key
 (
key
 will disappear) and hold in for 
20 seconds. This unlocks the thermostat.
Blank display any or keypad 
not responding
1. Voltage Spike or static discharge
Use the Reset Operation shown above.
Thermostat does not have 
Menu Screen Numbers
1. Earlier version of thermostat
To access the earlier version instruction sheet (37-6914E) 
go to www.white-rodgers.com, enter 1F95-1291 in Model 
Number Search 
 
Reset Operation
Note:
 If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the 
thermostat by removing the thermostat from the wall plate and removing batteries for 2 minutes. After two minutes, replace 
the batteries and replace thermostat on wall plate. If the thermostat has been reset and still does not function correctly contact 
your heating/cooling service person or place of purchase. 
www.white-rodgers.com
www.emersonclimate.com
TROUBLESHOOTING