The T-K2 Will Not Initiate 
First check the flow rate through the unit.  If the flow is not .75 GPM or greater, the unit will not 
initiate.  Check the filter and the flow sensor for any debris or damage. 
Press the lower green button on the GFCI inside the unit.  If the red light above it does not come on, 
then there is a problem with the electrical supply to the unit.  If that light does come on, hit the green 
reset button above the light, and look for the green light on the circuit plate at the top left of the unit.  
If this light is not lit, there is a problem with the electrical connection between the GFCI and the 
circuit plate.  Contact Takagi Industrial Company for Instructions. 
Error Codes 
All Takagi units are self diagnostic for errors.  If there is a problem with the installation or the unit, it 
will give a signal, through a pair of flashing lights on the circuit plate, to communicate the source of 
the problem.  If the unit has a TK-RE01 remote control installed, this 
will give also give a numerical error code.  Consult the following chart 
for the meaning of an error code: 
 
 
 
 
 
 
 
 
 
 
 
 
                  
                  TK-RE01 
 
 
Computer Board 
TK-RE01 Check 
Point 
11 Igniter 
12 Flame 
Detector 
51 Main 
Gas 
Valve 
Burning (red) LED: Blinking 
Power (green) LED: OFF 
72 Pre 
Post 
Check 
03 
Wrong Gas, Dip Switch  
14 Hi-Limit 
Switch 
70 Computer 
Board 
Burning (red) LED: OFF 
Power (green) LED: Blinking 
71 Proportional 
Valve 
61 Fan 
Motor 
Burning  LED and Power LED: 
Blinking Alternately 
21 Vent 
Pipe 
31 Thermistor 
Burning LED and Power LED:  
Blink Simultaneously 
65 Water 
Control 
Valve 
 
 
 