White Rodgers 1F90W-51 Manual De Usuario

Descargar
Página de 8
4
All wiring diagrams are for typical systems only.  Refer to
equipment manufacturers' instructions for specific sys-
tem wiring information.
To prevent electrical shock and/or equipment
damage, disconnect electrical power at the main
fuse box or circuit breaker until installation is
complete.
NOTE
CAUTION
!
RC
Y
24vAC
120vAC
Hot
Neutral
THERMOSTAT
SYSTEM
G
W
Figure 6.  Typical Wiring Diagram for Cool Only, 3-Wire, Single Transformer Systems
Fan
Relay
Cooling
System
RH
TRANSFORMER
G
RC
Y
W
RH
Thermostat Terminal Connections
G
From 24vAC
transformer
From fan relay
From cooling system
RC
Y
RH
Y
24vAC
120vAC
Hot
Neutral
THERMOSTAT
SYSTEM
G
W
Figure 5.  Typical Wiring Diagram for Heat Only,  3-Wire, Single Transformer Systems
TRANSFORMER
RC
Fan
Relay
Heating
System
JUMPER
WIRE
G
RC
Y
W
RH
W
RH
Thermostat Terminal Connections
G
From heating system
From 24vAC
transformer
From fan relay
CONNECT red jumper
wire (provided)
NOTE
RED jumper wire (pro-
vided with thermostat) 
must be connected be-
tween thermostat's RH 
and  RC terminals for pro-
per thermostat operation 
with this system.
RH
Y
24vAC
120vAC
Hot
Neutral
THERMOSTAT
SYSTEM
G
W
Figure 4.  Typical Wiring Diagram for Heating Only, 2-Wire, Single Transformer Systems
TRANSFORMER
Heating
System
RC
G
RC
Y
W
RH
W
RH
Thermostat Terminal Connections
From heating system
From 24vAC transformer