Western Telematic Remote Power Boot Switch Manual De Usuario

Descargar
Página de 12
2
RXD
Data Input
3
TXD
Data Output
4
DTR
Ready Output
5
GND
Signal Ground
6
(NC)
Not Connected
7
RTS
RTS Output
8
(NC)
Not Connected
9
(NC)
Not Connected
Coding:   Asynchronous.  7-8 bits, any parity
❍   
Data Rate:   2400, 9600 bps (Switch Selectable)
❍   
LEDs:   Power ON, Control Input, Plug On (5)
●   
Temperature:   0° C to 30° C (operating)
●   
Power:
115 VAC Model:   Internal 115 VAC 60 Hz
(15 Amps Maximum Load).
❍   
230 VAC Model:   Internal 230 VAC 60 Hz
(15 Amps Maximum Load).
❍   
●   
Size:   1.75" x 17.00" x 6.5" (H x W x D).
Requires one rack space.
●   
Mounting:   19" Rack Mount Bracket Included.
24" Rack Mount Bracket Optional.
●   
Weight: 5 pounds shipping weight
●   
Appendix B.   Customer Service
Customer Service hours are from 8:00 AM to 5:00 PM, PST, Monday through Friday.
 When calling, please be prepared to give the name and make of the unit, its serial number
and a description of its symptoms.  If the unit should need to be returned for factory repair it
must be accompanied by a Return Authorization number from Customer Service.
WTI Customer Service
5 Sterling
RPB+; Remote Power Boot Switch -- User's Guide
file:///C|/WEBPAGE/guides/rpbp/build/rpbpguid.htm (11 of 12) [3/9/2000 5:08:11 PM]