Bunn FMD-2 Manual De Usuario

Descargar
Página de 40
11
TROUBLESHOOTING (cont.)
PROBLEM
Product overflows container
Weak product
PROBABLE CAUSE
1. Dispense Switch
2. Dispense Solenoid Valve
1. Water Temperature
2. Whipper Motor
3. Frother
4. Dispense Solenoid Valve
5. Auger Drive - FMD-1
    Auger Drive - FMD-2
6. Auger Spring - FMD-1
    Auger Spring - FMD-2
7. Auger Motor - FMD-1
    Auger Motor - FMD-2
8. Rinse/Run Switch - FMD-1
    Rinse/Run Switch - FMD-2
9. Rinse Timer - FMD-2
REMEDY
Refer to 
Service -  Dispense Switch
for testing procedures. See page 21
Remove the solenoid valve and clear
any obstructions. Rebuild or replace
the valve if necessary. See page 34
Place an empty container beneath
the dispense tip. Initiate a dispense
cycle and check the water tempera-
ture immediately below the dispense
tip with a  thermometer.
Reading for mechanical thermostat
models should be 180
°
F to 200
°
F
(see thermostat temperature settings
decal in 
USER NOTICES on page 3.)
Refer to 
Service - Whipper Motor for
testing  procedure. See page 24
Refer to 
Service - Frother Compo-
nents. See page 24
Refer to 
Service - Dispense Solenoid
Valve for test procedures. See page
34
Refer to 
Service - Auger Drive Com-
ponents. See page 13
See page 15
Refer to 
Service - Auger Drive Com-
ponents. See page 13
See page 15
Refer to 
Service - Auger Drive Com-
ponents. See page 13
See page 15
Refer to 
Service - Rinse/Run Switch
for test procedures. See page 31
See page 32
Refer to 
Operation - Rinse Timer.
See Page 5
29112 101598