Bunn FCD-4 Manual De Usuario

Descargar
Página de 21
19
Dispense Fault List
“REFILL” indicator
Beeper
Fault
2 flashes
2 beeps
Dispense station locked out.
3 flashes
3 beeps
DISPENSE/RINSE sensing fault.
4 flashes
4 beeps
DISPENSE/RINSE knob mis-positioned.
5 flashes
5 beeps
Pump motor stalled/speed sensor inoperative.
All “REFILL”
3 beeps
Dispenser locked out.
indicators flash
3 times
Dip Switch Function List
Dip Switch Controls
Off
On
1
“REFILL” indicator when “concentrate out” is detected.
Inactive
Active
2
Lockout dispense components when “concentrate out” is detected.
Inactive
Active (Note)
3
Number of positions that can dispense/rinse simultaneously.
3
2
4
Rinse timer
Off
On
5
Audio feedback during dispenses.
On
Off
6
Future use.
None
None
Note: When dip switch 2 is in the “on” position, the “REFILL” indicator is active, regardless of dip switch 1
position.
Cooling Fault List
Fault Code
“COOLING”
DBC display
Fault
Fault
indicator
(optional)
Priority
8
8 flashes every
fault 8
Bath water level low.
1
5 seconds
(Also lights all “WATER” indicators)
7
7 flashes every
fault 7
Bath temperature probe short circuit.
2
5 seconds
6
6 flashes every
fault 6
Bath temperature probe open circuit.
3
5 seconds
5
5 flashes every
fault 5
Cabinet temperature probe short circuit.
4
5 seconds
4
4 flashes every
fault 4
Cabinet temperature probe open circuit.
5
5 seconds
3
3 flashes every
fault 3
Cooling system failure
6
5 seconds
(disables all dispense functions)
0
On steady
Bath/cabinet
Bath and cabinet temperatures excessive.
7
temperatures
2
2 flashes every
Bath/cabinet
Bath temperature excessive.
8
5 seconds
temperatures
1
1 flash every
Bath/cabinet
Cabinet temperature excessive.
9
5 seconds
temperatures
33496 030901