Bunn Beverage Dispenser FMD-5 Manual De Usuario

Descargar
Página de 71
41
SERVICE (cont.)
J1
LEVEL CONTROL BOARD AND LEVEL PROBE (FMD-1 only)
FIG. 34 LEVEL CONTROL BOARD AND PROBE
Location:
The level control board is located behind the lower 
access panel mounted on the right side of the compo-
nent bracket. 
The Level probe is located on the left center of the 
tank lid just in front of the overflow tube.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Remove the violet wire from terminal 1 & pink wire 
from terminal 4 of the circuit board.
3.  Check the voltage across terminals 2 & 3 with a 
voltmeter. Connect the dispenser to the power 
source. The  indication must be:
 
a) 120 volts ac for two wire 120 volt models.
  b) 120 volts ac for three wire 120/208 volt or 
120/240 volt models.
 
c) 230 volts ac for two wire 230 volt models.
P1665
4.  Disconnect the dispenser  from the power 
source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the wiring 
diagram and check the dispenser wiring haness.
5.   Reconnect the violet wire to terminal 1.
6.  Carefully connect a piece of insulated jumper wire 
to terminal 4. Keep the other end of this wire away 
from any metal surface of the dispenser.
7.  Check the voltage across terminals 1 & 3 with a 
voltmeter. Connect the dispenser to the power 
source. The indication must be:
 
a) 120 volts ac for two wire 120 volt models,
  b) 120 volts ac for three wire 120/208 volt or 
120/240 volt models,
 
c) 230 volts ac for two wire 230 volt models, after 
a delay of approximately 5 seconds.
8.  Touch the free end of jumper wire to the component 
bracket. The indication must be 0.
9.  Move the jumper wire away from the component 
bracket. The indication must again be:
 
a) 120 volts ac for two wire 120 volt models,
  b) 120 volts ac for three wire 120/208 volt or 
120/240 volt models,
 
c) 230 volts ac for two wire 230 volt models, after 
a delay of approximately 5 seconds.
10. Disconnect the dispenser from the power source 
and remove the jumper wire from terminal 4.
If voltage is present as described, the level control board 
is operating properly, proceed to #11.
If voltage is not present as described, replace the level 
control board.
11. Reconnect the pink wire to terminal 4.
12. Gently pull the probe out of the tank lid and inspect 
for corrosion. Replace it if necessary.
42672 122209