If continuity is present as described, the auger switch 
is operating properly.
If continuity is not present as described, replace the 
auger switch.
Removal and Replacement:
1.  Pull the dispenser drawer out until the drawer hits 
the drawer stop. Using a screwdriver gently pry up 
on the drawer stop and remove the drawer from 
the dispenser.
2.  Remove the four #8-32 locking screws securing 
the switch panel to the drawer.
3.  Lift the switch panel with wires and L.E.D./adjust-
ment board out as an assembly.
4.  Turn switch panel over and remove the wires from 
the auger switch that is to be replaced.
5.  Compress the clips on the back of the control panel 
and gently push switch through the opening.
6.  Push the new switch into the opening, with the “o” 
on the switch to the outside, until the clips snap 
into position.
7.  Reconnect the wires to the switch. Refer to Fig. 8 
when reconnecting wires. 
8.  Position  the  switch  panel  inside  the  drawer  and 
secure with four #8-32 locking screws.
9.  Reinstall drawer.
FIG. 8 AUGER SWITCH TERMINALS
P1336
FIG. 7 AUGER ON/OFF SWITCHES
P1343
Location:
 
The auger switches are located inside the dispenser 
drawer.
Test Procedures:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the white/green wire from the switch 
to be tested and white/black wire from contactor 
located on the outside bottom of the component 
bracket .
3.  With a voltmeter, check the voltage across the white/
green and the white/black wires and the “ON/OFF” 
switch in the “ON” position. Connect the dispenser 
to the power source. The indication must be:
 
a) 120 volts ac for 120 volt models.
 
b) 230 volts ac for 230 volt models.
4.  Disconnect the dispenser from the power source.
If voltage is present as described, reconnect the white/
black wire to the contactor and proceed to #5.
If voltage is not present as described, refer to the Wiring 
Diagram and check the dispenser wiring harness.
5.  Remove the white/blue wire from the right auger 
switch, the white/brown wire from the left auger 
switch,  or  the  grey  wire  from  the  center  auger 
switch.
6.  With  the  auger  switch  to  be  tested  in  the  “ON” 
position check for continuity across the terminals. 
Continuity must not be present when the switch is 
in the “OFF” position.
SERVICE (cont.)
AUGER ON/OFF SWITCHES