Bunn Beverage Dispenser CDS-3 Manual De Usuario

Descargar
Página de 60
46
R2
2
FIG.45 SOLENOID TERMINALS
P1327
SERVICE (cont.)
SOLENOIDS
FIG. 44 SOLENOIDS
P1342
Location:
The  solenoids  are  mounted  on  a  bracket  that  is 
attached on top of the chassis on the left side.
Test Procedures: 
1.  Disconnect the dispenser from the power source.
2.  Disconnect the white/black wire from the solenoid 
to be tested and the orange wire from the left sole-
noid, the violet wire from the right solenoid or the 
white/violet wire from the center solenoid.
3.  With  a  voltmeter,  check  the  voltage  across  the 
white/black wire and the other wire with the ON/OFF 
switch  in  the  “ON”  position  and  the  appropriate 
ICE/OFF/NO-ICE switch in the “ICE” or “NO-ICE” 
position. Connect the dispenser to the power source. 
The indication must be:
 
a) 120 volts ac for 120 volt models.
 
b) 230 volts ac for 230 volt models.
4.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #5
If  voltage  is  not  present  as  described,  refer  to  the 
Wiring Diagram and check the dispenser main wiring 
harness.
5.  Check for continuity across the solenoid valve coil 
terminals.
If  continuity  is  present  as  described,  reconnect  the 
wires to the solenoid.
If continuity is not present as described, replace the 
solenoids.
6.  Check the solenoid valve for coil action. Connect 
the dispenser to the power source. With the auger 
motor  switch  in  the  “ON”  position  and  the  ON/
OFF/ICE switch in the “ICE” or “NO-ICE” position 
press the ON/OFF switch to the “ON” position. After 
approximately two minutes listen carefully in the 
vicinity of the solenoid valve for a “clicking” sound 
as the coil magnet attracts.
7.  Disconnect the dispenser from the power source.
If the sound is heard as described and the refrigerant 
will not pass through the solenoid valve, there may be 
a blockage in the refrigerant line before the solenoid 
valve, or the solenoid valve may require inspection for 
wear, and removal of particles.
If  the  sound  is  not  heard  as  described,  replace  the 
solenoids. 
Removal and Replacement:
NOTE: Before removal of any refrigeration component 
the refrigerant in the system must be reclaimed by a 
licensed refrigeration repair person.
1.  Disconnect the wires from both solenoids.
2.  Disconnect the refrigerant lines from the solenoids 
to the cooling drums and the refrigerant line from 
the accumulator.
3.  Remove  the  #6  hex  crimptite  securing  solenoid 
bracket to the dispenser chassis.
4.  Remove bracket and solenoids from the chassis 
assembly.
5.  Remove the four #8-32 locking screws securing 
the solenoids to the bracket.
6.  Remove solenoid and repair or discard.
7.  Install  new  solenoid  on  mounting  bracket  using 
four #8-32 locking screws.
8.   Reinstall mounting bracket and solenoids inside the 
dispenser chassis, securing with a #6 hex crimptite 
screw.
9.  Reconnect the tubes from the accumulator and the 
cooling drums.
10. Refer to Fig. 45 and reconnect the wires.
11. Evacuate the system.
12. Recharge the system with the appropriate coolant 
and to the pressures directed on the decals
NOTE: The charging of the system must be done by a 
licensed refrigeration repair person.
27646 122200