Bunn VLPF Manual De Propietario

Descargar
Página de 28
Page 26                                    
START SWITCH
FIG. 22 START SWITCH
P2172.80
BLU to Timer
WHI/ RED to On/ Left Switch
WHI/ RED to Liquid Level 
Control Board
P1987
FIG. 23 START SWITCH TERMINAL
SERVICE (cont.)
10179 060100
Location:
  The Start switch is located in front of the hood, 
centered above the brew funnel.
Test Procedure:
1.  Disconnect the brewer from the power source and 
remove the wires from both terminals of the Start 
switch.
2.  Check for continuity across the two terminals on 
the switch when it is held in the lower position. 
Continuity must not be present across these ter-
minals in the upper position.
If continuity is present as described, reconnect the 
wires, the switch is operating properly. (It does not 
matter which terminals the wires are installed on).
If continuity is not present as described, replace the 
switch.
Removal and Replacement:
1.  Remove all wires from the switch terminals.
2.  Compress the clips inside the hood and gently 
push the switch through the opening.
3.  Push the new switch into the opening and spread 
the clips to hold the switch captive in the hood.
4.  Refer to the FIG 23. When reconnecting the 
wires.