Bunn VLPFCanada Manual De Propietario

Descargar
Página de 28
 
 
 
 
 
 
 
 
Page 25      
SERVICE (cont.)
SOLENOID VALVE
PN
: 65
8
BUNN
OFF
HI
FIG. 20 SOLENOID VALVE
P2173.80
10179 060100
Location:
 
The solenoid valve is located in the left rear  corner 
of the hood.
Test Procedures:
1.  Disconnect the brewer from the power source and 
remove both wires from the solenoid valve coil 
terminals.
2.  With a voltmeter, check the voltage across the white 
and white/blue wires when the On/Left switch is in 
the upper position and the Start switch is pressed 
to the lower position and released. Connect the 
brewer to the power source. The indication must 
be 120 volts ac for the approximate setting on the 
brew timer dial and then return to zero.
3.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the Wir-
ing Diagram and check the brewer wiring harness.
4.  Check  for  continuity  across  the  solenoid  valve 
coil.
If continuity is present as described, reconnect the 
white and white/blue wires and proceed to #5.
If continuity is not present as described, replace the 
solenoid valve.
5.  Check the solenoid valve for coil action. Connect 
the brewer to the power source, place the On/Left 
switch in the upper position, press and release the 
Start switch. Listen carefully in the vicinity of the 
solenoid valve for a “clicking” sound as the coil 
magnet attracts and after the approximate setting 
on the brew timer dial, repels the plunger.
6.  Disconnect the brewer from the power source.
If the sound is heard as described and water will not 
pass through the solenoid valve, there may be a block-
age in the water line before or after the solenoid valve 
or, the solenoid valve may require inspection for wear, 
and removal of waterborne particles.
If the sound is not heard as described, replace the 
solenoid valve.
Removal and Replacement:
1.  Remove all wires from the solenoid valve coil.
2.  Turn off the water supply to the brewer.
3.  Disconnect the water lines to and from the sole-
noid valve.
4.  Remove the two #8-32 nuts holding the solenoid 
valve mounting bracket to the hood.
5.  Lift out the solenoid valve.
6.  Remove  the  solenoid  valve  from  the  mounting 
bracket.
7.  Securely  install  the  new  solenoid  valve  to  the 
mounting bracket.
8.  Attach the mounting bracket to the hood.
9.  Securely fasten the water lines to and from the 
solenoid valve.
10. Refer to FIG. 21 when reconnecting the wires.
WHI to Right  Switch
WHI to Liquid  Level 
Control  Board
WHI/BLU to Relay
P1989
FIG. 21 SOLENOID TERMINALS