Bunn Single SH DBC* (with Smart Funnel) Manual De Propietario

Descargar
Página de 50
Page 35
FACTORY DEFAULTS
 
This function allows the operator to erase all of the 
previously entered recipes and ad messages. Factory-
set default values will replace all previous settings.
EXIT 
EXIT 
REPLACE 
WILL REPLACE ALL 
BREW SETTINGS 
ARE YOU SURE? 
NO                     YES 
FACTORY DEFAULTS 
NO                     YES 
Procedure to set factory defaults:
1.  Press and hold the ® pad until SET NEW RECIPES 
appears. Release the ® pad.  Press and release ® 
until the display reads FACTORY DEFAULTS.
2. Pressing NO in this screen will revert to the MAIN 
SCREEN.  Press YES to replace the defaults.  This 
advances to WILL REPLACE ALL BREWING SET-
TINGS.  This screen will alternate with ARE YOU 
SURE?.
3. Pressing NO in the confirmation screen will revert 
to MAIN SCREEN, without resetting the brewing 
setups to the defaults. Press YES to load the de-
faults. This will then revert to the MAIN SCREEN
and the factory default values will replace all 
previously entered values. It will NOT reset the 
summation Brew counter.
P2312
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
FACTORY DEFAULT VALUES
Brew Lockout 
YES
BREW VOLUMES:
Small Batch 
64 oz.
Medium Batch 
128 oz.
Large Batch 
192 oz.
BYPASS PERCENTAGE: 
Small Batch 
0%
Medium Batch 
20%
Large Batch 
20%
PULSE BREW TIMES:
Small Batch 
40 - 1st on; 10 - off; 5 last on
Medium Batch 
OFF
Large Batch 
OFF
PREINFUSION TIMES:
Small Batch 
OFF
Medium Batch 
OFF
Large Batch 
OFF
DRIP OUT TIMES:
Small Batch 
1:00
Medium Batch 
1:30
Large Batch 
2:00
ENABLE ADS 
YES
BREW TEMPERATURE 
200˚F (93˚C)
READY TEMPERATURE 
195˚F (91˚C)
REFILL 155
SPRAY (OZ/MINUTE) 
39.2
BYPASS (OZ/MINUTE) 
24.1
FUNNEL DETECT 
YES
SERVER DETECT 
YES
 
34025  022509