ELECTRICAL REQUIREMENTS
CAUTION - Do not connect the brewer to the power source until specified in Initial Set-Up.
MODELS  OL15  &  20  require 
2-wire, grounded service rated 
120 volts ac, 15 or 20 amp re-
spectively, single phase, 60 Hz.  
MODELS OL35 & RL35 require 
3-wire, grounded service rated 
120/208 or 120/240 volts ac, 20 
amp, single phase, 60 Hz.
Electrical Hook-Up
Model OL15 has an attached cordset.
Models OL20, OL35, & RL35, proceed as follows:
CAUTION – Improper electrical installation will damage 
electronic components.
1. 
An electrician must provide electrical service as 
specified.
2. 
Using  a  voltmeter,  check  the  voltage  and 
color coding of each conductor at the electrical 
source.
3. 
Remove  the  top  panel  and  rotate  the  control 
thermostat knob fully counterclockwise to the 
“OFF” position and replace the panel.
4. 
Remove the rear panel, feed the cord through 
the strain relief, and connect it to the terminal 
block.
5. 
Connect  the  brewer  to  the  power  source  and 
verify the voltage at the terminal block before 
proceeding.  Replace the rear panel. 
 
6. 
If plumbing is to be hooked-up later be sure the 
brewer is disconnected from the power source.  
If Plumbing has been hooked-up, the brewer is 
ready for Initial Set-Up.
PLUMBING REQUIREMENTS
 
This brewer must be connected to a cold water 
system with operating pressure between 20 and 90 
psi from a 1/2” or larger supply line.  A shut-off valve 
should be installed in the line before the brewer.  Install 
a regulator in the line when pressure is greater than 
90 psi to reduce it to 50 psi.  The water inlet fitting is 
1/4” flare.
NOTE - Bunn-O-Matic recommends 1/4” copper tubing 
for installations of less than 25 feet and 3/8” for more 
than 25 feet from the 1/2” water supply line.  A tight 
coil of copper tubing in the water line will facilitate 
moving the brewer to clean the counter top.  Bunn-O-
Matic does not recommend the use of a saddle valve 
to install the brewer.  The size and shape of the hole 
made in the supply line by this type of device may 
restrict water flow.
MODELS OLA, RLA, OL35B & 
RL35B require 2-wire, ground-
ed  service  rated  240  volts  ac 
or 200 volts ac, 20 amp single 
phase, 50 Hz.
P1478
MODEL  OL25B  requires 
2-wire,  grounded  service 
rated 100 volts ac, 20 amp 
single phase, 50 Hz.
32430 010308
L2 RED
L1 BLACK
200, 230 or
240V A.C.
This equipment must be installed to comply with 
the International Plumbing Code of the International 
Code Council and the Food Code Manual of the Food 
and Drug Administration (FDA). For models installed 
outside the U.S., you must comply with the applicable 
Plumbing/Sanitation Code for your area.