Bunn LCA-2 LP Manual De Propietario

Descargar
Página de 26
21
CALIBRATING THE DISPENSER (Cont.)
 
LCD DISPLAY 
 CALIBRATION MODE 
 DESCRIPTION
Right (Decaf) Water Rate
Set PRIME-NORMAL-RINSE switch to 
RINSE position. Press and hold Decaf 
Dispense Switch until flow stops (20 
sec.) Refer to Field Calibration of the 
Concentrate Pumps.
Right (Decaf) Water Rate
Enter Liters collected from the 20 sec. 
test above.
Default = 1.08
Range = 0.95 - 1.12 Liters
Pump “OFF” Delay
Delays the Pump turn off after a 
dispense.
Default = 200
Range = 1 - 999 mSec.
Reset Factory Defaults
Resets all set up values to the Factory 
Default setting.
Hold both Increase (+)  and  Decrease 
(-) switch for 10 seconds.
Displays Software Version # -
Exits To Home View After 3 Seconds.
English or Metric Mode
Eng for English
S.I. for Metric
Error Code History
Displays last known Error Code
Depress the Decrease (-) to view the 
last 3 Errors.
Hold the Decrease (-) & Increase (+) 
switches for 10 sec. to Erase.
38791 072307
MENU
(-)
(+)
C 4 r u n
MENU
(-)
(+)
C 4 1.0 8
MENU
(-)
(+)
C 6 2 0 0
MENU
(-)
(+)
C 7 E n g
MENU
(-)
(+)
- - -
C 8
MENU
(-)
(+)
- - -
C 9
MENU
(-)
(+)
x x
C
L