Bunn LCR-2 Manual De Propietario

Descargar
Página de 38
28
Activate the Dispenser within 5 sec. to 
dispense the pre-selected volume.
Front Panel LED Display Messages
Alternate Portion Dispenser 
Volume #2 has been selected
Portion LED “ON”
Portion Dispense 
Enabled
Rinse Dispenser, see Rinse Procedure
Dispenser Locked Out
Rinse Cycle Required
Rinse LED “FLASHING” 
Rinse Lockout Enabled
Rinse Dispenser, see Rinse Procedure
Rinse Cycle Required
Rinse LED “ON”      
Rinse Timer
Check Tank Temp Setting
Check Ready Temp. Setting
Service Required: Change the Supply Voltage, 
see Optional Field Wiring
Usage has exceeded the 
capacity of the Tank Heater
Ready LED “OFF”
Water Temp. Too Low
Check Power Cord
Check the AC Power Circuit Breaker
Service Required
Dispenser Not plugged in.  
AC Circuit Breaker OFF
 Power LED “OFF”
No AC Power
Troubleshooting
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems 
encountered.  If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic 
Technical Service Department.
•  Only qualified service personnel should perform inspection, testing, and repair of electrical equipment.
•  Shorting the terminals or the application of external voltages to electronic components may result in component 
or circuit board failure.
•  Intermittent operation of electronic circuit boards is unlikely. board failure will normally be permanent. If an 
intermittent condition is encountered, the cause will likely be a switch contact or a loose wire connection at 
a terminal or crimp.
•  Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are 
energized for more than ten minutes without a supply of water.
•  The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will 
help avoid twists and kinks in the tubing.
•  Make certain that all plumbing connections are sealed and all electrical connections are tight and isolated.
•  This dispenser is heated at all times.  Keep away from combustibles.
WARNING:
•  Exercise extreme caution when servicing electrical equipment.
•  Disconnect the brewer from the power source when servicing, except when electrical tests are specified. The 
red “Power LED” on the door indicates that the unit is connected to AC Power.
•  Follow recommended service procedures.
•  Replace all protective shields or safety notices.
36026.1 010313