Bunn LCR-2 Manual De Propietario

Descargar
Página de 38
34
Dispenser Flow Rate Calibration
13. Press Down Arrow Key to display the CAL LF WTR FLO menu screen.
14. Place a 64 Oz (2000 ml) graduated container under Left Dispense Tip and Pull the Left Dispense Handle 
momentarily. The dispenser will dispense water for 20 seconds and then shut OFF automatically.
15. Keep the graduated container under dispense tip until all the water stops dripping.
16. Measure the volume of water collected in the graduated container.
Acceptable ranges for the volume collected
_____Dispenser Flow Rate___________   ____Volume Collected____
1.8 Oz/sec (53 ml/sec) w/ flow restrictor  
 
32 - 38 Oz, (946 - 1124 ml)
 2.5 Oz/sec (74 ml/sec) w/o flow restrictor    
46 - 52 Oz ,(1360 - 1538 ml)
17. If the amount collected is not within the acceptable range, empty the graduated container and repeat 
STEPS 14 – 16
18. If the amount collected is still not within range, inspect the dispense valves, tubing and mix chamber for 
lime, kinks or other obstructions.
19. When satisfied with the volume of concentrate collected, press the Down Arrow Key.
20. The CAL LF WTR VOL screen will be displayed. Use the (-) / (+) keys to adjust number displayed to the 
amount measured in STEP 16.
21. Press Down Arrow Key again to exit the CAL LEFT SIDE functions.
Calibrating the Right Side Dispenser
Repeat STEPS 1-21 above  for the “CAL RIGHT SIDE” menus.
Field Calibration of the Concentrate Pumps / Dispenser Flow Rates
(Continued)
36026.1 010313
Field Calibrating the Hot Water Flow Rate
1.  Locate the programming module and use the Arrow Down key to scroll through the LCD screen until “CAL 
HOT WTR FLO?” appears.
2.  Place a 64 Oz (2000 ml) graduated container under Hot Water Tip and press the hot water switch. The unit 
will dispense Hot Water for 20 seconds and then shut OFF automatically. Keep the graduated container under 
the dispense tip until all the water stops dripping.
3.  Measure the volume of water collected in the graduated container. The acceptable range for the volume 
collected is 32 - 38 Oz. (946 - 1124 ml).
4.  If the amount collected is not within the acceptable range, empty the container and repeat steps 2 & 3.
5.  If the amount collected is still not within range, inspect the hot water valve, tubing and fittings for lime, kinks, 
or other obstructions.
6.  When satisfied with the volume of concentrate collected, press the Down Arrow Key.
7.  The “CAL HOT WTR VOL” screen will be displayed. Use the (-) / (+) keys to adjust number displayed to the 
ammount measured in step 3.
8.  Press Down Arrow Key again to exit this function.