Bunn Dual SH DBC (/5, 1/0 gal) Manual De Propietario

Descargar
Página de 9
Page 7
29877.5 020413
INITIAL SETUP
CAUTION: The brewer must be disconnected from the power source throughout the initial setup, except when 
specified in the instructions.
1.  Insert an empty funnel into the funnel rails of one of the 
brew stations.
2.  Place an empty server under the funnel.
3.  Connect the brewer to the power source. Main ON/OFF 
Switch (located in bottom cover behind right front leg on 
some brewers) must be in the ON position. Water will begin 
flowing into the tank and stop when the tank is filled to its 
capacity. Display will show PLEASE WAIT...TANK FILLING 
until tank is filled with water.
4.  Wait approximately twenty minutes for the water in the 
tank to heat to the proper temperature. Display will show 
READY TO BREW...WATER TEMP: XXX˚ when tank is at 
operating temperature.
 
NOTE: Brew water temperature is factory set at 200° F 
(93.3° C). Refer to TEMPERATURE SELECTION  below 
should the water temperature need to be increased or 
decreased. When brew water temperature is changed, 
ready temperature should be increased or decreased ac-
cordingly.
5.  Place a small vessel beneath the faucet and open the faucet 
handle. Release it when you hear the tank refilling.
6.  Water volumes have been preset at the factory. Refer 
to adjustments for the Set Brew Volumes section of the 
Programming Manual on the Bunn-O-Matic website, at 
www.bunn.com should the volume need to be increased or decreased.
7.  The brewer is now ready for use in accordance with the coffee brewing instructions.
TEMPERATURE SELECTION
SET TEMP  - Range: 185˚F (85˚C) to 205˚F (96˚C)
  This function allows the operator to set the brew water temperature in the tank.  It also sets the hot water 
faucet dispense temperature.
Procedure to set brew temperature:
1.  Press and hold upper right hidden switch until the display reads SELECT RECIPE. Release switch.  Continue 
to press and release switch until the display reads  SET TEMP.
2.  To adjust the brew temperature, press (-) to decrease or (+) to increase the brew temperature.
3.  When finished, press and release DONE to save the new setting, exit the SET TEMP function and advance to 
the next function screen,  SET READY. Another alternative is to press and release  the ON/OFF switch (either 
on DUAL brewers) located on the front switch panel to exit the SET TEMP function and return to the MAIN 
SCREEN.
°
°
°
°
SET TEMP: XXX°
 (-)  DONE  (+)