ELECTRICAL REQUIREMENTS
120V AC 
Single phase models
Note: 
This electrical service re-
quires 2 current carrying conduc-
tors (Neutral, and L1) and a separate 
conductor for earth ground.
Requirements for brewers without an attached cord set are as follows:
Requirements for brewers with an attached cord set are as follows:
120V
120/208-240V
For Supply Connections, Use No. 12 AWG
Wires Suitable For At Least 90
°C (194°F)
FOR USE ONLY ON AN
INDIVIDUAL BRANCH
CIRCUIT RATED 20 AMPS
120V
120/208-240V
For Supply Connections, Use No. 12 AWG
Wires Suitable For At Least 90
°C (194°F)
FOR USE ONLY ON AN
INDIVIDUAL BRANCH
CIRCUIT RATED 20 AMPS
Dual Voltage Switch 
in 120V position
Dual Voltage Switch in 
120/208-240V position
120/208 & 120/240V AC 
Single phase models
Note: 
This electrical service 
requires 3 current carrying 
conductors (Neutral, L1 and 
L2) and a separate conductor 
for earth ground.
Single & Dual Volt Models
N
L1
G
L2 RED
L2 RED
POWER CORD
WHITE
GREEN
NEUTRAL
L1 BLACK
WHITE
NEUTRAL
L2
L1 BLACK
WHITE
NEUTRAL
L1 BLACK
N
L1
G
POWER CORD
GREEN
WHITE
NEUTRAL
L1 BLACK
L2 RED
L2 RED
L2
L1 BLACK
L1
G
POWER CORD
GREEN
L1 BLACK
120/208-240V 3 WIRE + GROUND
120V 2 WIRE + GROUND
208-240V 2 WIRE + GROUND
L2 RED
NEUTRAL BLUE
N
L1 BLACK
L1
G
POWER CORD
GREEN/YELLOW
L1 BROWN
220-240V 2 WIRE + GROUND
A & B Models
N
L1
G
L2 RED
L2 RED
POWER CORD
WHITE
GREEN
NEUTRAL
L1 BLACK
WHITE
NEUTRAL
L2
L1 BLACK
120/208-240V 3 WIRE + GROUND