Bryant 548J***D Manual De Usuario

Descargar
Página de 10
548J***D
SINGLE PACKAGE ROOFTOP
HIGH--EFFICIENCY HEAT PUMP UNITS
WITH FIELD--INSTALLED ELECTRIC HEAT
SIZES 17 & 24 WITH PURON(R--410A) REFRIGERANT
Submittal Data
Certified to ISO
Use of the AHRI Certified
TM Mark indicates a
manufacturer’s  
participation in the 
program For verification 
of certification for individual 
products, go to 
www.ahridirectory.org.
9001:2000
DESCRIPTION
548J***D units are one--piece, two--stage heat pump units
that are low profile, prewired, tested and charged at the
factory. These are intended for installation on a roof curb
accessory (ordered separately), or for slab mounting (for
horizontal duct connections). Units are designed to accept
field--installed electric heaters. Units may be ordered with
various factory--installed options. Field--installed accessories
are also available.
STANDARD FEATURES
Base Unit
S
Puron (R--410A) HFC refrigerant
S
EER’s up to 10.8
S
IEER’s up to 11.5
S
COP’s up to 3.3
S
ASHRAE 90.1 energy compliant
S
Rated in accordance with AHRI Standard 340/360
S
Designed in accordance with Underwriters’ Laboratories
Standard 1995
S
Two--stage cooling capacity control on all models
S
Non--corrosive composite sloping design; side or center drain
condensate pan. Meets ASHRAE Standard 62
S
Cooling operating range from 30_F up to 115_F
(--1_C up to 46_C).
S
Dedicated vertical nd horizontal airflow models available,
ordered as factory option. No special kits required
S
Two--inch disposable return air filters
S
Thru--the--bottom power entry capability
S
Single point electric connections on field--installed electric heat
units
S
24--volt control circuit protected with resettable circuit breaker
and 75--VA transformer
S
Belt drive, constant torque, permanently lubricated
evaporator--fan motor on all size units.
S
Totally enclosed condenser motors with permanently lubricated
bearings
S
State--of--the--art defrost control board, easily configured for
defrost cycles of 30, 60, 90, or 120 minutes.
S
Centralized Terminal Board for component and unit wiring
connections.
S
Loss of Charge, High--Pressure, and Freeze Protection switches
S
Full perimeter base rail with built--in rigging adapters and fork
truck slots.
Cabinet
S
Access panels with easy grip handles
S
Innovative, easy starting, no strip screw features on unit access
panels.
S
Pre--painted exterior panels and primer--coated interior panels
tested to 500 hours salt spray protection
S
Fully insulated cabinet
S
Tool--less filter access door
Refrigerant System
S
Acutrolt refrigerant metering system
S
Liquid line filter drier
S
Scroll compressors with internal line--break overload protection
S
Indoor and outdoor coils constructed of aluminum fins
mechanically bonded to seamless copper tubes.
S
Removable gauge line plugs for reading refrigerant pressure
with unit panels in place
S
Four--way reversing valve operation
S
Suction Line Accumulator standard -- prevents excessive liquid
flood back of refrigerant to the compressor even during the start
of the defrost cycle.
Standard Parts Warranty
S
5--year electric heater (field--installed)
S
5--year compressor
S
1--year parts