Black Box IC476A-F-R2 Manual De Usuario
![Black Box](https://files.manualsbrain.com/attachments/93f582e81b91156050f0dfb0bd85a42bc8635e07/common/fit/150/50/2f54d4d876583e31f45c92e398ef3997c2dece9a115125c2fd1224ff9c81/brand_logo.png)
19
CHAPTER 4: Installation
4.2 Connection to the RS-232 Interface
Once you have properly configured the Converter and connected the
twisted-pair wires correctly, simply plug the Converter directly into the
DB25 port of the RS-232 device. After doing so, remember to insert and
tighten the two captive connector screws.
NOTE
If you must use a cable to connect the Converter to the RS-232 device,
make sure it is a straight-through cable of the shortest possible length.
We recommend no more than 6 ft. (1.8 m).
make sure it is a straight-through cable of the shortest possible length.
We recommend no more than 6 ft. (1.8 m).
4.3 Wiring for Multipoint Applications
The Converter supports multipoint applications using daisychain topology.
Using a daisychain topology, you may connect several Converters together
Using a daisychain topology, you may connect several Converters together
in a master/slave arrangement. Maximum distance between the units will
vary based upon the number of drops, data rate, wire gauge, etc.
The illustration below shows how to wire the two-pair (4-wire) cables
The illustration below shows how to wire the two-pair (4-wire) cables
properly for a daisychain topology. Note that the ground connection is not
needed.
NOTE
Connections are to screw terminals directly on the Converter.
XMT A
XMT B
RCV B
RCV A
XMT A
XMT A
RCV B
RCV B
RCV B
RCV B
RCV A
RCV A
RCV A
RCV A
XMT A
XMT A
XMT B
XMT B
XMT B
XMT B
MASTER
SLAVE 1
SLAVE 2
SLAVE 3
SLAVE N