System Unit
System Unit
System Unit
System Unit
Dimensions
Dimensions
Dimensions
Dimensions (HxWxD)
(with feet/bezel)
3.38 x 17.54 x 26.01 in (8.59 x 44.54 x 66.07 cm)
Weight 
Weight 
Weight 
Weight (approximate)
Maximum
60 lb (27.22 kg)
Minimum
47.18 lb (20.41 kg)
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
Rated Line Voltage
100-132 VAC, 200-240 VAC
Rated Input Current
10A (100VAC), 10A (120VAC), 6.1A (200VAC)
Rated Input Frequency
50 to 60 Hz
Rated Input Power
1000/1056/1205 W
BTU Rating
BTU Rating
BTU Rating
BTU Rating
BTU/HR
3490/3680/4150
Power Specifications
Power Specifications
Power Specifications
Power Specifications
To review typical system power ratings use the Active Answers Power
Calculator which is available via the online tool located at URL:
To drill down to calculators:
- Click on: "ProLiant Servers"
- Click on the Server of interest. Example: DL380 G5
- Click on: "Power Calculator" link. (You may need to scroll down to see it.)
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
Power
Power
Power
Power
(per power supply)
Rated Steady-State Power 800/850/1000 W
Maximum Peak Power
800/850/1000 W
Temperature Range
Temperature Range
Temperature Range
Temperature Range
Operating
50° to 95° F (10° to 35° C) at sea level with an
altitude de-rating of 1.8° F per 1000 ft (1.0° C
per 304.8 m) to 10,000 ft (3048 m) no direct
sunlight allowed. Maximum rate of change is 18°
F/Hr (10° C/Hr). Upper operating limit is 10,000
ft (3,048 m) or 70 Kpa/10.1 psia.
System performance may be reduced if operating
with a fan fault or above 30° C.
Non-operating
-22° to 140° F (-30° to 60° C) Maximum rate of
change is36° F/Hr (20° C/Hr). Upper non-
operating limit is 30,000 ft (9,144 m) or
30.3KPa/4.4 psia.
Maximum Wet Bulb
Maximum Wet Bulb
Maximum Wet Bulb
Maximum Wet Bulb
Temperature
Temperature
Temperature
Temperature
101.7° F (38.7° C)
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Operating
10% to 90% relative humidity (Rh), 28° C
maximum wet bulb temperature.
Non-operating
5% to 95% relative humidity (Rh), 38.7° C
maximum wet bulb temperature.
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
Idle Minimum (Fixed Disk
Drives Spinning)
 
L WAd (BELS)
6.1
L pAm (dBA)
44
Operating Minimum
(Random Seeks to Fixed
Disks)
 
LLLL WAd (BELS)
6.1
L pAm (dBA)
44
QuickSpecs
HP ProLiant DL380 G5 Storage Server
HP ProLiant DL380 G5 Storage Server
HP ProLiant DL380 G5 Storage Server
HP ProLiant DL380 G5 Storage Server
Technical Specifications
DA - 12559   EMEA — Version 20 — November 17, 2008
Page 49