14540
LC-1000 Lube System Controller
76.2
(3.00)
DIMENSIONS mm / (Inches)
114.3
(4.50)
127.0
(5.00)
114.3 (4.50)
4.8 (.19)
POWER
LUBE
FAULT
CYCLE
LUBE SYSTEM
CONTROLLER
TIME  COUNTS  REMAINING
MANUAL RUN
PRGM
ENTER
MODEL   LC-1000
MANUAL
RUN BUTTON
127.0
(5.00)
ORDERING INFORMATION
PROGRAMMING INSTRUCTIONS
The LC-1000 Controller has icons in the display to indi-
cate if the unit is in a lube ON cycle or OFF cycle and to 
show the timing mode.  They are also used to indicate 
which counter is being adjusted when programming new 
parameters.  The LCD four digit display is used to show 
the remaining time left in either an ON or OFF cycle, as 
indicated by the icons.  Timing can be done in seconds, 
minutes, hours or counts.  A fl ashing LCD character 
indicates that the timer is in the Programming mode.
VOLTAGE
PART NUMBER
12 VDC
163-400-050
24 VDC
163-400-051
115 VAC, 50/60 Hz
163-400-052
230 VAC 50/60 Hz
163-400-053
VOLTAGE
PART NUMBER
12 VDC
572-144-644
24 VDC
572-144-645
115 VAC, 50/60 Hz
572-144-646
230 VAC 50/60 Hz
572-144-647
Replacement Board
LC-1000 Controller
PUSH BUTTONS:
There are four mini push buttons;
PRGM - Initiate Program mode, or alternate between  
    settings 
for:
 ON 
 
(Monitor 
Time)
 OFF 
 
(Pause 
Time)
 CYCLE 
 
(Switch 
Transitions)
 PUMP 
 
(Pulsed 
On 
Time)
  S - Increase digit
  X - Next digit select
ENTER - Enter (save) new setting and advance to 
     
next 
program 
step.
S
X