Brother LK3-B448E Manual De Usuario
LK3-B448E MARK
II
/BA-16
17
3. Installation
3-16. Installing the operation panel
The operation panel can be installed to either the top or bottom of the work table.
3-17. Connecting the ground wire
CAUTION
Be sure to connect the ground. If the ground connection is not secure, you run the risk of receiving a
serious electric shock, and problems with correct operation may also occur.
serious electric shock, and problems with correct operation may also occur.
1. Install the operation panel presser plate
q
to the top of the button feeder cover with the two screws
w
.
2. Insert the panel
e
into the operation panel presser plate
q
, and then secure it with the two screws
r
.
3. Insert the connector cord
t
into the control box through the hole at the side of the box. Refer to “3-13. Connecting
the cords” for details on connecting the cord.
Red
White
Black
Yellow/Green ....... Connect to ground
Connect to the power switch. However, the
black wire is insulated to the inside of the
box and is not used.
black wire is insulated to the inside of the
box and is not used.
r
w
q
e