Failure  to  follow  and  read  all  instructions  carefully   
before  installing  or  operating  this  control  could  cause 
personal injury and/or property damage
Installation Instructions for 
Heating & Air Conditioning 
1F78
Non-Programmable Thermostat 
CONTENTS
Preparations .................................................. 1
Thermostat Details ........................................ 1
Removing Old Thermostat ............................. 1
Mounting and Wiring ...................................... 2
Check Thermostat Operation ......................... 3
Specifications ................................................ 5
Troubleshooting ............................................. 5
YOUR THERMOSTAT REPLACES
Typical System Compatibility Chart 
1F78
Standard Heat Only Two Wire Gas or Oil Fired Systems (24 volt) 
Yes
Electronic Ignition Heat Only Two Wire Systems (24 volt) 
Yes
Electronic Ignition Heat Only Gas or Oil Fired Systems (24 volt) 
Yes
Standard Heat/Cool Systems (24 volt) 
Yes
Heat/Cool Systems Electric Heat (24 volt) 
Yes
Heat Only Electric Heat Systems (24 volt) 
Yes
Cool Only Systems (24 volt) 
Yes
Heat Pump Systems (No Aux or Emergency Heat) 
Yes
Hot Water Zone Heat Only (Two Wire) Systems 
Yes
Hot Water Zone Heat Only (Three Wire) Systems 
No
Line Voltage Heating or Baseboard 110/240 Volt Systems 
No
Millivolt Systems Floor or Wall Furnaces 
Yes
12 VDC Mobile Home Application 
Yes
Multistage Systems 
No
Systems Exceding 30VAC, 1.5 Amp 
No
2
  THERMOSTAT DETAILS
Mounting
hole
Mounting
hole
W904
Clip for
Celsius
Display
W905 Clip 
for Hydronic 
System
Electric/Gas
Switch
W
RH
B
RC
G
O
Y
+
-
+
-
GAS
ELEC
W904
W905
Figure 1. Thermostat
NOTE: Earlier models refer to 37-7006 for jumper locations.
HAND OR POWER 
DRILL WITH 3/16 INCH 
DRILL BIT, IF NEEDED
FLAT BLADE SCREWDRIVER
WIRE CUTTER/STRIPPER
1
  PREPARATIONS
To  prevent  electrical  shock  and/or  equipment  damage, 
disconnect electrical power to the system at the main fuse 
or circuit breaker until installation is complete.
CAUTION
!
Before  removing  wires  from  old  thermostat’s  switching  subbase, 
label  each  wire  with  the  terminal  designation  it  was  removed 
from.
1.
  Remove  Old Thermostat:    A  standard  heat/cool  thermostat 
consists of three basic parts:
 
a.  The cover, which may be either a snap-on or hinge type.
 
b.  The base, which is removed by loosening all captive screws.
 
c.  The switching subbase, which is removed by unscrewing  
 
  the mounting screws that hold it on the wall or adaptor plate.
2.
  Shut  off  electricity  at  the  main  fuse  box  until  installation  is 
complete. Ensure that electrical power is disconnected.
3.
  Remove the front cover of the old thermostat. With wires still 
attached, remove wall plate from the wall. If the old thermostat 
has a wall mounting plate, remove the thermostat and the wall 
mounting plate as an assembly.
4.
  Identify each wire attached to the old thermostat using the 
labels enclosed with the new thermostat.
5.
  Disconnect the wires from the old thermostat one at a time. DO 
NOT LET WIRES FALL BACK INTO THE WALL.
6.
  Install new thermostat using the following procedures.
PART NO. 37-6615C
Replaces 37-6615B
1028
Assemble tools required below.
3
  REMOVING OLD THERMOSTAT
www.white-rodgers.com
www.emersonclimate.com